Part Number
Definition:
A COMPONENT WHICH CONVERTS AVAILABLE ALTERNATING CURRENT OR DIRECT CURRENT ELECTRICAL POWER INTO A FORM REQUIRED TO OPERATE ANOTHER COMPONENT OR SET. THE ITEM MAY CONSIST OF A COMBINATION OF AN INVERTOR, VIBRATOR; VIBRATOR, INTERRUPTER; VIBRATOR, SELF-RECTIFYING; INVERTOR, POWER, STATIC; WITH A TRANSFORMER AND RECTIFIER(S) EMPLOYING ELECTRON TUBES, SEMICONDUCTOR DIODE OR METALLIC (DRY DISC) TYPE COMPONENTS, OR THE SYNCHRONIZED SECONDARY CONTACT(S) OF A VIBRATOR, SELF-RECTIFYING; OR MAY CONSIST OF ELECTRON TUBES, SEMICONDUCTOR DIODE OR METALLIC (DRY DISC) TYPE RECTIFIERS AND CAPACITORS IN TRANSFORMERLESS (ALTERNATING CURRENT-DIRECT CURRENT TYPE) CIRCUITS WHICH MAY BE OF THE VOLTAGE-MULTIPLIER TYPE. THE ITEM MAY INCORPORATE A FILTER, DIRECT CURRENT POWER AND PROVISIONS FOR REGULATION OF INPUT AND/OR OUTPUT VOLTAGE. THE ITEM MAY HAVE SPECIAL INPUT, OUTPUT, CONTROL OR OTHER FACILITIES FOR APPLICATIONS IN SPECIALIZED ENVIRONMENTS SUCH AS MEDICAL, DENTAL OR OTHER OPERATIONS. EXCLUDES BATTERY CHARGERS AND ROTATING MACHINERY TYPES OF ITEMS, SUCH AS MOTOR GENERATORS AND DYNAMOTORS.
CAGE Information
Code | Company |
---|---|
80103 | VEECO INSTRUMENTS INC LAMBDA DIV |
Federal Supply Class
Title
CONVERTERS, ELECTRICAL, NONROTAT
Inclusions:
INCLUDES COMPLETE BATTERY CHARGING EQUIPMENT, NONROTATING; POWER SUPPLIES, MULTIAPPLICATION.
Exclusions:
EXCLUDES RECTIFYING TUBES; (FSC 5960); RECTIFYING CRYSTALS (FSC 5961); ROTATING EQUIPMENT (FSC 6125); TRANSFORMERS (FSC 5950); AND SEMICONDUCTOR DEVICES AND ASSOCIATED HARDWARE (FSC 5961).
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
BGHX | OUTPUT CONTROL QUANTITY | 2 2ND POWER OUTPUT |
BGHX | OUTPUT CONTROL QUANTITY | 2 2ND POWER OUTPUT |
BGHX | OUTPUT CONTROL QUANTITY | 2 3RD POWER OUTPUT |
BGHY | OUTPUT CONTROL TYPE | COARSE VOLTAGE ADJUSTMENT 1ST POWER OUTPUT AND FINE CURRENT ADJUSTMENT 1ST POWER OUTPUT AND COARSE CURRENT ADJUSTMENT 1ST POWER OUTPUT AND FINE VOLTAGE ADJUSTMENT 1ST POWER OUTPUT |
CBBL | FEATURES PROVIDED | FILTER |
CWGH | OUTPUT CURRENT RATING | 800.0 DC MILLIAMPERES MINIMUM 1ST POWER OUTPUT AND 1.4 DC AMPERES MAXIMUM 1ST POWER OUTPUT |
ABHP | OVERALL LENGTH | 10.094 INCHES NOMINAL |
AKWC | ELECTRICAL POWER SOURCE RELATIONSHIP | OPERATING |
BGHY | OUTPUT CONTROL TYPE | COARSE VOLTAGE ADJUSTMENT 2ND POWER OUTPUT AND COARSE CURRENT ADJUSTMENT 2ND POWER OUTPUT AND FINE CURRENT ADJUSTMENT 2ND POWER OUTPUT AND FINE VOLTAGE ADJUSTMENT 2ND POWER OUTPUT |
ABMK | OVERALL WIDTH | 8.375 INCHES NOMINAL |
APPA | OUTPUT VOLTAGE RATING | 0.0 DC VOLTS MINIMUM 1ST POWER OUTPUT AND 120.0 DC VOLTS MAXIMUM 1ST POWER OUTPUT |
BHQN | RECTIFICATION METHOD | SINGLE PHASE FULL WAVE CENTER TAP |
APNX | INPUT VOLTAGE RATING | 105.0 AC POUNDS PER HOUR DRY SINGLE OPERATING POWER RQMT AND 132.0 AC POUNDS PER HOUR WITH RETAINING CHAIN SINGLE OPERATING POWER RQMT |
CWHF | OUTPUT CONNECTION QUANTITY | 2 1ST POWER OUTPUT |
CWHJ | OUTPUT CONNECTION TYPE | BINDING POST 1ST POWER OUTPUT AND TERMINAL STRIP 1ST POWER OUTPUT |
ABKW | OVERALL HEIGHT | 5.188 INCHES NOMINAL |
CWHF | OUTPUT CONNECTION QUANTITY | 2 2ND POWER OUTPUT |
APTQ | INPUT FREQUENCY RATING | 47.0 HERTZ MINIMUM SINGLE OPERATING POWER RQMT AND 440.0 HERTZ MAXIMUM SINGLE OPERATING POWER RQMT |
CWHF | OUTPUT CONNECTION QUANTITY | 2 3RD POWER OUTPUT |
CWGH | OUTPUT CURRENT RATING | 400.0 DC MILLIAMPERES MINIMUM 2ND POWER OUTPUT AND 700.0 DC MILLIAMPERES MAXIMUM 2ND POWER OUTPUT |
BGHY | OUTPUT CONTROL TYPE | COARSE VOLTAGE ADJUSTMENT 3RD POWER OUTPUT AND COARSE CURRENT ADJUSTMENT 3RD POWER OUTPUT AND FINE CURRENT ADJUSTMENT 3RD POWER OUTPUT AND FINE VOLTAGE ADJUSTMENT 3RD POWER OUTPUT |
CWGH | OUTPUT CURRENT RATING | -400.0 DC MILLIAMPERES MINIMUM 3RD POWER OUTPUT AND -700.0 DC MILLIAMPERES MAXIMUM 3RD POWER OUTPUT |
ANPM | INPUT PHASE | SINGLE SINGLE OPERATING POWER RQMT |
CWHJ | OUTPUT CONNECTION TYPE | BINDING POST 2ND POWER OUTPUT AND TERMINAL STRIP 2ND POWER OUTPUT |
AYNH | OPERATING AMBIENT TEMP RANGE | +0.1/+60.0 DEG CELSIUS |
CWHJ | OUTPUT CONNECTION TYPE | BINDING POST 3RD POWER OUTPUT AND TERMINAL STRIP 3RD POWER OUTPUT |
BGHX | OUTPUT CONTROL QUANTITY | 2 1ST POWER OUTPUT |
APPA | OUTPUT VOLTAGE RATING | 0.0 DC VOLTS MINIMUM 2ND POWER OUTPUT AND 60.0 DC VOLTS MAXIMUM 2ND POWER OUTPUT |