Part Number
Part Number:
NSN:
NIIN:
Item Name:
RELAY , ELECTROMAGNETIC
Definition:
A RELAY WHICH IS ACTUATED BY THE EFFECT OF A MAGNETIC FIELD DEVELOPED BY THE CURRENT IN ITS ENERGIZING COIL(S). INCLUDES SOLENOID AND ARMATURE TYPES. EXCLUDES CONTACTOR, MAGNETIC; RELAY, METER MOVEMENT; RELAY, MOTOR DRIVEN; RELAY, REED; RELAY, RESONANT REED; RELAY, ROTARY; AND SWITCH, STEPPING.
CAGE Information
Code | Company |
---|---|
98897 | LOCKHEED MARTIN CORPORATION DBA LOCK |
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
CWAB | MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 28.0 DC |
AKDX | WINDING QUANTITY | 1 |
ABKW | OVERALL HEIGHT | 0.390 INCHES MINIMUM AND 0.410 INCHES MAXIMUM |
ABHP | OVERALL LENGTH | 1.330 INCHES MAXIMUM |
TTQY | TERMINAL TYPE AND QUANTITY | 10 PIN ALL FUNCTIONS |
ABMK | OVERALL WIDTH | 0.410 INCHES MAXIMUM |
APCN | COIL QUANTITY | 1 |
CBBL | FEATURES PROVIDED | LATCHING CONTACTS |
CSXF | OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 26.5 VOLTS TEARDROP, TWO HOLES TYPE 4F SINGLE WINDING |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 1.068 INCHES MINIMUM SINGLE MOUNTING FACILITY AND 1.088 INCHES MAXIMUM SINGLE MOUNTING FACILITY |
APNA | WINDING DC RESISTANCE RATING | 1.0 KILOHMS NOMINAL SINGLE WINDING |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 2 UNTHREADED HOLE SINGLE MOUNTING FACILITY |
ADZC | ENVIRONMENTAL PROTECTION | HERMETIC |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 2.0 AMPERES DC RESISTIVE LOAD |
ZZZK | SPECIFICATION/STANDARD DATA | 36659-LS15474 MANUFACTURERS STANDARD |
APNP | DUTY TYPE | CONTINUOUS |
AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.110 INCHES MINIMUM SINGLE MOUNTING FACILITY AND 0.130 INCHES MAXIMUM SINGLE MOUNTING FACILITY |
CRNG | NONPILE-UP MAIN CONTACT ARRANGEMENT | 2 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
TEST | TEST DATA DOCUMENT | 81349-MIL-R-5757 SPECIFICATION |
CQYJ | MOUNTING FACILITY PATTERN | IN-LINE SINGLE MOUNTING FACILITY |