Part Number
Part Number:
NSN:
NIIN:
Item Name:
RELAY , THERMAL
Definition:
A RELAY SWITCH WHICH IS ACTUATED BY THE EFFECT OF INTERNAL HEAT GENERATED BY THE CURRENT IN ITS ENERGIZING CIRCUIT. FOR ITEMS ACTUATED BY AMBIENT, RATHER THAN INTERNAL TEMPERATURE CHANGES, SEE SWITCH, THERMOSTATIC.
CAGE Information
Code | Company |
---|---|
93929 | SPX CORPORATION DBA RADIODETECTION |
Federal Supply Class
Title
RELAYS AND SOLENOIDS
Inclusions:
INCLUDES ELECTROMAGNETIC ACTUATORS.
Exclusions:
EXCLUDES CONTRACTORS.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
CYCS | CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 115.0 AC AND 28.0 DC |
CYCW | DELAY TIME IN SECONDS | 5.0 FIXED OPERATE NOMINAL |
APFR | CONTACT ARRANGEMENT | SINGLE POLE, SINGLE THROW, NORMALLY CLOSED |
CYCT | CONTACT MAXIMUM CURRENT RATING IN AMPS | 2.0 AC OR 1.0 DC |
ABKW | OVERALL HEIGHT | 1.000 INCHES NOMINAL |
CYCV | HEATER POWER RATING IN WATTS | 4.0 |
CYCU | HEATER VOLTAGE RATING IN VOLTS | 28.0 |
FEAT | SPECIAL FEATURES | TWO 0.130 IN. DIA MTG HOLES SPACED 1.125 IN. C TO C |
ABMK | OVERALL WIDTH | 1.380 INCHES NOMINAL |
ABHP | OVERALL LENGTH | 1.188 INCHES NOMINAL |
TTQY | TERMINAL TYPE AND QUANTITY | 4 PIN |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 2 UNTHREADED HOLE |