Part Number
Part Number:
NSN:
NIIN:
Item Name:
TERMINAL , LUG
Definition:
A TERMINAL DESIGNED TO BE AFFIXED, USUALLY AT ONE END, TO A POST, STUD, CHASSIS, OR THE LIKE FOR MOUNTING. IT HAS PROVISIONS FOR ATTACHMENT OF WIRE(S) OR SIMILAR ELECTRICAL CONDUCTOR(S) IN ORDER TO ESTABLISH AN ELECTRICAL CONNECTION AND COULD REQUIRE THE USE OF TOOL(S) FOR ATTACHMENT OF WIRE. FOR POST LIKE TERMINALS, SEE TERMINAL STUD. EXCLUDES CLIP, ELECTRICAL; TERMINAL, QUICK DISCONNECT AND TERMINAL FEEDTHRU.
CAGE Information
Code | Company |
---|---|
80249 | BAE SYSTEMS INFORMATION AND ELECTRON |
Federal Supply Class
Title
LUGS, TERMINALS, AND TERMINAL ST
Inclusions:
INCLUDES BINDING POSTS; BATTERY CLIPS; STUD TERMINALS; TEST CLIPS.
Exclusions:
EXCLUDES CAPS, ELECTRICAL; CLIPS, ELECTRICAL; AND CONTACTS, ELECTRICAL.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AALB | LARGEST WIDTH | 0.290 INCHES SINGLE END |
SFTT | SURFACE TREATMENT | TIN MOUNTING FACILITY SINGLE LAYER |
MATT | MATERIAL | COPPER ALLOY CONDUCTOR ACCOMMODATION |
AAJU | OVERALL LENGTH | 0.922 INCHES |
CSFJ | CONDUCTOR ACCOMMODATION TYPE | FLAT LUG SLOTTED W/ONE HOLE SINGLE END |
AAMK | MOUNTING FACILITY THICKNESS | 0.031 INCHES |
AAMC | MOUNTING TONGUE WIDTH | 0.280 INCHES |
SFTT | SURFACE TREATMENT | TIN CONDUCTOR ACCOMMODATION SINGLE LAYER |
AALX | MOUNTING METHOD STYLE | STRAIGHT TWO HOLE |
AAMA | MOUNTING HOLE DIAMETER | 0.144 INCHES |
CSXT | DISTANCE FROM MOUNTING HOLE CENTER TO MOUNTING END | 0.157 INCHES |
AALV | ELECTRICAL INSULATION FEATURE | UNINSULATED |
AAJX | MATERIAL THICKNESS | 0.031 INCHES |
AGTA | BASIC SHAPE STYLE | SOLDER |
AAKV | MAXIMUM CONDUCTOR SIZE ACCOMMODATED | 11 AWG |
AAJV | OVERALL WIDTH | 0.280 INCHES |
ADHV | CENTER TO CENTER DISTANCE BETWEEN MOUNTING HOLES ALONG LENGTH | 0.312 INCHES |
MATT | MATERIAL | COPPER ALLOY MOUNTING FACILITY |