RELAY , ELECTROMAGNETIC

Definition:

A RELAY WHICH IS ACTUATED BY THE EFFECT OF A MAGNETIC FIELD DEVELOPED BY THE CURRENT IN ITS ENERGIZING COIL(S). INCLUDES SOLENOID AND ARMATURE TYPES. EXCLUDES CONTACTOR, MAGNETIC; RELAY, METER MOVEMENT; RELAY, MOTOR DRIVEN; RELAY, REED; RELAY, RESONANT REED; RELAY, ROTARY; AND SWITCH, STEPPING.

CAGE Information

Code Company
58657 LEACH INTERNATIONAL CORPORATION DBA

Characteristics (Decoded)

MRC Requirements Statement Clear Text Reply
CSXF OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP 28.0 VOLTS DC 125 DEG CELSIUS SECOND WINDING AND 115.0 VOLTS AC 125 DEG CELSIUS SECOND WINDING
TTQY TERMINAL TYPE AND QUANTITY 14 PIN ENERGIZING ELEMENT
ABKW OVERALL HEIGHT 16.3 MILLIMETERS NOMINAL
ABMK OVERALL WIDTH 20.6 MILLIMETERS NOMINAL
ABKQ CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH 27.0 MILLIMETERS MINIMUM SINGLE MOUNTING FACILITY AND 27.4 MILLIMETERS MAXIMUM SINGLE MOUNTING FACILITY
CQYJ MOUNTING FACILITY PATTERN TRIANGLE SINGLE MOUNTING FACILITY
AEBV UNTHREADED MOUNTING HOLE DIAMETER 3.4 MILLIMETERS NOMINAL SINGLE MOUNTING FACILITY
AFRH CONTACT SURFACE TREATMENT TIN PLATED
ABHP OVERALL LENGTH 20.6 MILLIMETERS NOMINAL
AXHR MOUNTING FACILITY TYPE AND QUANTITY 3 UNTHREADED HOLE SINGLE MOUNTING FACILITY
AJSS FREQUENCY IN HERTZ 400.0 NOMINAL
CRPQ NOMINAL OPERATING CURRENT RATING AND TYPE 5.0 AMPERES DC SECOND WINDING AND 5.0 AMPERES AC SECOND WINDING
ADZC ENVIRONMENTAL PROTECTION CORROSION RESISTANT AND HERMETIC
ABKR CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH 12.7 MILLIMETERS NOMINAL SINGLE MOUNTING FACILITY