Part Number
Definition:
A RIGID OR FLEXIBLE TUBING HAVING UNIFORM INSIDE AND OUTSIDE DIAMETERS IN THE OVERALL LENGTH. IT IS SPECIFICALLY DESIGNED TO PREVENT ANY UNDESIRABLE FLOW OF CURRENT BETWEEN CONDUCTORS AND OTHER OBJECTS. INCLUDES SHRINKABLE TYPE TUBING, ITEMS IN BULK AND IN SPECIFIC FABRICATED LENGTHS (CUT TO SIZE). EXCLUDES ITEMS NOT HAVING RATED ELECTRICAL CHARACTERISTICS. ALSO EXCLUDES BUSHING, SLEEVE; CABLE NIPPLE, ELECTRICAL; CONDUIT (AS MODIFIED); INSULATION SLEEVING, ELECTRICAL, SPECIAL PURPOSE; INSULATION SLEEVING, THERMAL; SLEEVE, MARKER, CABLE; SLEEVING, TEXTILE, ELECTRICAL; TUBING, GLASS; AND TUBING, NONMETALLIC.
CAGE Information
Code | Company |
---|---|
81343 | SOCIETY OF AUTOMOTIVE ENGINEERS INC |
Federal Supply Class
Title
ELECTRICAL INSULATORS AND INSULA
Inclusions:
INCLUDES TUBE, KNOB, CLEAT, STRAIN, AND STANDOFF INSULATORS; FEED THRU INSULATORS; BEAD INSULATORS; VARNISH CAMBRIC TAPE; FRICTION TAPE.
Exclusions:
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
STYL | STYLE DESIGNATOR | SHRINKABLE |
FLEX | FLEXIBILITY | FLEXIBLE |
ABHP | OVERALL LENGTH | ANY ACCEPTABLE |
ABJH | TEMP RATING | -67.0 DEG CELSIUS AND 200.0 DEG CELSIUS |
AFZN | RECOVERED WALL THICKNESS | 0.012 INCHES NOMINAL |
CQBC | MINIMUM TENSILE STRENGTH | 2000 POUNDS PER SQUARE INCH |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
UKBG | DIELECTRIC MATERIAL VOLTAGE RATING PER UNIT THICKNESS | 500.0 VOLTS PER MIL /0.001 INCH/ |
ADZC | ENVIRONMENTAL PROTECTION | FLAME RESISTANT AND CORROSION RESISTANT AND MILDEW RESISTANT AND WATER RESISTANT |
HUES | COLOR | CLEAR |
MATL | MATERIAL | PLASTIC,FLUORINATED ETHYLENE PROPYLENE,MIL-I-23053/11,CLASS 1 |
AGAU | HEAT SHRINKAGE RATING IN PERCENT | 20.7 |
AFZL | EXPANDED INSIDE DIAMETER | 0.440 INCHES MINIMUM |
AFZM | RECOVERED INSIDE DIAMETER | 0.349 INCHES MAXIMUM |