Part Number
Definition:
A RIGID OR FLEXIBLE TUBING HAVING UNIFORM INSIDE AND OUTSIDE DIAMETERS IN THE OVERALL LENGTH. IT IS SPECIFICALLY DESIGNED TO PREVENT ANY UNDESIRABLE FLOW OF CURRENT BETWEEN CONDUCTORS AND OTHER OBJECTS. INCLUDES SHRINKABLE TYPE TUBING, ITEMS IN BULK AND IN SPECIFIC FABRICATED LENGTHS (CUT TO SIZE). EXCLUDES ITEMS NOT HAVING RATED ELECTRICAL CHARACTERISTICS. ALSO EXCLUDES BUSHING, SLEEVE; CABLE NIPPLE, ELECTRICAL; CONDUIT (AS MODIFIED); INSULATION SLEEVING, ELECTRICAL, SPECIAL PURPOSE; INSULATION SLEEVING, THERMAL; SLEEVE, MARKER, CABLE; SLEEVING, TEXTILE, ELECTRICAL; TUBING, GLASS; AND TUBING, NONMETALLIC.
CAGE Information
Code | Company |
---|---|
81343 | SOCIETY OF AUTOMOTIVE ENGINEERS INC |
Federal Supply Class
Title
ELECTRICAL INSULATORS AND INSULA
Inclusions:
INCLUDES TUBE, KNOB, CLEAT, STRAIN, AND STANDOFF INSULATORS; FEED THRU INSULATORS; BEAD INSULATORS; VARNISH CAMBRIC TAPE; FRICTION TAPE.
Exclusions:
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
STYL | STYLE DESIGNATOR | SHRINKABLE |
ABHP | OVERALL LENGTH | ANY ACCEPTABLE |
ABJH | TEMP RATING | -55.0 DEG CELSIUS AND 110.0 DEG CELSIUS |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
AFZM | RECOVERED INSIDE DIAMETER | 0.195 INCHES MAXIMUM |
AFZL | EXPANDED INSIDE DIAMETER | 0.500 INCHES MINIMUM |
CQBC | MINIMUM TENSILE STRENGTH | 1500 POUNDS PER SQUARE INCH |
UKBG | DIELECTRIC MATERIAL VOLTAGE RATING PER UNIT THICKNESS | 500.0 VOLTS PER MIL /0.001 INCH/ |
AFZN | RECOVERED WALL THICKNESS | 0.055 INCHES NOMINAL |
MATL | MATERIAL | PLASTIC, POLYOLEFIN |
FEAT | SPECIAL FEATURES | MELTABLE INNER WALL; MATERIAL SPEC: MIL-I-23053/4, CLASS 1 |
AGAU | HEAT SHRINKAGE RATING IN PERCENT | 61.0 |
HUES | COLOR | BLUE |
FLEX | FLEXIBILITY | SEMIRIGID |
ADZC | ENVIRONMENTAL PROTECTION | CORROSION RESISTANT AND MILDEW RESISTANT AND WATER RESISTANT |