Part Number
Definition:
A RIGID OR FLEXIBLE TUBING HAVING UNIFORM INSIDE AND OUTSIDE DIAMETERS IN THE OVERALL LENGTH. IT IS SPECIFICALLY DESIGNED TO PREVENT ANY UNDESIRABLE FLOW OF CURRENT BETWEEN CONDUCTORS AND OTHER OBJECTS. INCLUDES SHRINKABLE TYPE TUBING, ITEMS IN BULK AND IN SPECIFIC FABRICATED LENGTHS (CUT TO SIZE). EXCLUDES ITEMS NOT HAVING RATED ELECTRICAL CHARACTERISTICS. ALSO EXCLUDES BUSHING, SLEEVE; CABLE NIPPLE, ELECTRICAL; CONDUIT (AS MODIFIED); INSULATION SLEEVING, ELECTRICAL, SPECIAL PURPOSE; INSULATION SLEEVING, THERMAL; SLEEVE, MARKER, CABLE; SLEEVING, TEXTILE, ELECTRICAL; TUBING, GLASS; AND TUBING, NONMETALLIC.
CAGE Information
Code | Company |
---|---|
81343 | SOCIETY OF AUTOMOTIVE ENGINEERS INC |
Federal Supply Class
Title
ELECTRICAL INSULATORS AND INSULA
Inclusions:
INCLUDES TUBE, KNOB, CLEAT, STRAIN, AND STANDOFF INSULATORS; FEED THRU INSULATORS; BEAD INSULATORS; VARNISH CAMBRIC TAPE; FRICTION TAPE.
Exclusions:
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AFZL | EXPANDED INSIDE DIAMETER | 0.375 INCHES NOMINAL |
STYL | STYLE DESIGNATOR | SHRINKABLE |
ADZC | ENVIRONMENTAL PROTECTION | CORROSION RESISTANT AND FLAME RESISTANT AND MILDEW RESISTANT |
ABHP | OVERALL LENGTH | ANY ACCEPTABLE |
AFZM | RECOVERED INSIDE DIAMETER | 0.187 INCHES NOMINAL |
CQBC | MINIMUM TENSILE STRENGTH | 5000 POUNDS PER SQUARE INCH |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
UKBG | DIELECTRIC MATERIAL VOLTAGE RATING PER UNIT THICKNESS | 500.0 VOLTS PER MIL /0.001 INCH/ |
AFZN | RECOVERED WALL THICKNESS | 0.009 INCHES MINIMUM AND 0.015 INCHES MAXIMUM |
AGAV | END ITEM IDENTIFICATION | SUPPORT EQUIPMENT,F-16 AIRCRAFT |
ABJH | TEMP RATING | -55.0 DEG CELSIUS AND 175.0 DEG CELSIUS |
MATL | MATERIAL | PLASTIC, POLYVINYLIDENE FLUORIDE, MIL-I-23053/8 |
FLEX | FLEXIBILITY | SEMIRIGID |
HUES | COLOR | YELLOW |