Definition:

A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.

CAGE Information

Code Company
81349 MILITARY SPECIFICATIONS PROMULGATED

Federal Supply Class

Title

COILS AND TRANSFORMERS

Inclusions:

INCLUDES COILS, EXCEPT IGNITION AND MAGNETO; COIL ASSEMBLIES; REACTORS; TRANSFORMERS.

Exclusions:

Characteristics (Decoded)

MRC Requirements Statement Clear Text Reply
CQLC WINDING TAP LOCATION (NON-CORE) CENTER TAP SINGLE COMPONENT 3RD SECONDARY
AKPV MOUNTING FACILITY QUANTITY 4 SINGLE GROUP
CBME CUBIC MEASURE (NON-CORE) 57.72 CUBIC INCHES
ZZZK SPECIFICATION/STANDARD DATA 81349-MIL-T-27/301 GOVERNMENT SPECIFICATION
ADAU BODY HEIGHT 4.375 INCHES MINIMUM AND 4.625 INCHES MAXIMUM
CRBZ WINDING OPERATING CURRENT 1.44 AMPERES NOMINAL B AND BETTER DROP SIDING SINGLE COMPONENT SINGLE PRIMARY
CRMJ WINDING POWER RATING 15.0 VOLTS-AMPERES SINGLE COMPONENT 2ND SECONDARY
CWJS WINDING OPERATING VOLTAGE 5.00 AC POUNDS PER HOUR WET SINGLE COMPONENT 2ND SECONDARY
TTQY TERMINAL TYPE AND QUANTITY 11 TURRET
PKWT UNPACKAGED UNIT WEIGHT (NON-CORE) 10.000 POUNDS
CWJS WINDING OPERATING VOLTAGE 105.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY AND 115.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY AND 125.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY
BPLC WINDING FUNCTION AND QUANTITY 1 PRIMARY SINGLE COMPONENT AND 3 SECONDARY SINGLE COMPONENT
ADAT BODY WIDTH 3.563 INCHES MINIMUM AND 3.813 INCHES MAXIMUM
TEST TEST DATA DOCUMENT 81349-MIL-T-27 SPECIFICATION
AEHZ MAXIMUM OPERATING TEMP 105.0 DEG CELSIUS
ABKQ CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH 3.187 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 3.437 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
CRBZ WINDING OPERATING CURRENT 3.0 AMPERES NOMINAL B SINGLE COMPONENT 2ND SECONDARY
AAJF THREAD DIRECTION (NON-CORE) RIGHT-HAND SINGLE GROUP
AARG RELIABILITY INDICATOR NOT ESTABLISHED
AKNA INCLOSURE TYPE HERMETICALLY SEALED
CWJS WINDING OPERATING VOLTAGE 6.30 AC POUNDS PER HOUR WET SINGLE COMPONENT 1ST SECONDARY
AXGY MOUNTING METHOD THREADED STUD SINGLE GROUP
CRMJ WINDING POWER RATING 50.4 VOLTS-AMPERES SINGLE COMPONENT 1ST SECONDARY
CRBZ WINDING OPERATING CURRENT 175.0 MILLIAMPERES MAXIMUM OF STANDARD RANGE B SINGLE COMPONENT 3RD SECONDARY
CWJS WINDING OPERATING VOLTAGE 800.00 AC POUNDS PER HOUR WET SINGLE COMPONENT 3RD SECONDARY
ACZX WINDING SHIELDING METHOD INTERNAL SHIELD GROUNDED TO CORE SINGLE COMPONENT
ACZC INPUT-OUTPUT PHASE RELATIONSHIP SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
CRMJ WINDING POWER RATING 165.6 VOLTS-AMPERES SINGLE COMPONENT SINGLE PRIMARY
ADAQ BODY LENGTH 4.187 INCHES MINIMUM AND 4.437 INCHES MAXIMUM
THSD THREAD SERIES DESIGNATOR UNF SINGLE GROUP
AAJD THREAD CLASS (NON-CORE) 2A SINGLE GROUP
ABKR CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH 2.563 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 2.813 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
CQLC WINDING TAP LOCATION (NON-CORE) MULTIPLE TAPS W/O CENTER TAP SINGLE COMPONENT SINGLE PRIMARY
CQJX NOMINAL THREAD SIZE 0.190 INCHES SINGLE GROUP
CRBZ WINDING OPERATING CURRENT 8.0 AMPERES NOMINAL B SINGLE COMPONENT 1ST SECONDARY
ACZB FREQUENCY RATING 60.0 HERTZ NOMINAL SINGLE COMPONENT