TRANSFORMER , POWER

Definition:

A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.

CAGE Information

Code Company
81349 MILITARY SPECIFICATIONS PROMULGATED

Federal Supply Class

Title

COILS AND TRANSFORMERS

Inclusions:

INCLUDES COILS, EXCEPT IGNITION AND MAGNETO; COIL ASSEMBLIES; REACTORS; TRANSFORMERS.

Exclusions:

Characteristics (Decoded)

MRC Requirements Statement Clear Text Reply
AKPV MOUNTING FACILITY QUANTITY 4 SINGLE GROUP
ACZF MAXIMUM TRANSFORMER POWER RATING 375.0 VOLT-AMPERE SINGLE COMPONENT
AAJF THREAD DIRECTION (NON-CORE) LEFT-HAND SINGLE GROUP
AAJD THREAD CLASS (NON-CORE) 2B SINGLE GROUP
AKNA INCLOSURE TYPE FULLY INCLOSED
TTQY TERMINAL TYPE AND QUANTITY 10 TURRET
BPLC WINDING FUNCTION AND QUANTITY 1 PRIMARY SINGLE COMPONENT AND 3 SECONDARY SINGLE COMPONENT
THSD THREAD SERIES DESIGNATOR UNC SINGLE GROUP
TEST TEST DATA DOCUMENT 81349-MIL-T-27 SPECIFICATION
ACZC INPUT-OUTPUT PHASE RELATIONSHIP THREE PHASE TO THREE PHASE SINGLE COMPONENT
ADAT BODY WIDTH 3.240 INCHES MAXIMUM
ADAQ BODY LENGTH 4.990 INCHES MAXIMUM
AARG RELIABILITY INDICATOR NOT ESTABLISHED
AXGY MOUNTING METHOD THREADED HOLE SINGLE GROUP
AEHZ MAXIMUM OPERATING TEMP 130.0 DEG CELSIUS
CQJX NOMINAL THREAD SIZE 0.164 INCHES SINGLE GROUP
CWJS WINDING OPERATING VOLTAGE 200.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY
CQLC WINDING TAP LOCATION (NON-CORE) CENTER TAP SINGLE COMPONENT SINGLE PRIMARY
ACZD TRANSFORMER WINDING CONNECTION TYPE WYE-DELTA
CWJS WINDING OPERATING VOLTAGE 28.00 AC POUNDS PER HOUR WET SINGLE COMPONENT 1ST SECONDARY
ADAU BODY HEIGHT 1.940 INCHES MAXIMUM
ZZZK SPECIFICATION/STANDARD DATA 81349-MIL-T-27/349 GOVERNMENT SPECIFICATION
ACZB FREQUENCY RATING 400.0 HERTZ NOMINAL SINGLE COMPONENT
PKWT UNPACKAGED UNIT WEIGHT (NON-CORE) 3.800 POUNDS
ABKQ CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH 4.450 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
CRBZ WINDING OPERATING CURRENT 4.47 AMPERES NOMINAL B SINGLE COMPONENT 1ST SECONDARY
ABKR CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH 2.700 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
CRBZ WINDING OPERATING CURRENT 2.58 AMPERES NOMINAL B SINGLE COMPONENT 2ND SECONDARY
CWJS WINDING OPERATING VOLTAGE 48.50 AC POUNDS PER HOUR WET SINGLE COMPONENT 2ND SECONDARY

Similar Parts

M27/349-04 , M2734904 , 5950-01-350-3702 , 5950013503702 , 013503702