Part Number
Definition:
A RIGID OR FLEXIBLE TUBING HAVING UNIFORM INSIDE AND OUTSIDE DIAMETERS IN THE OVERALL LENGTH. IT IS SPECIFICALLY DESIGNED TO PREVENT ANY UNDESIRABLE FLOW OF CURRENT BETWEEN CONDUCTORS AND OTHER OBJECTS. INCLUDES SHRINKABLE TYPE TUBING, ITEMS IN BULK AND IN SPECIFIC FABRICATED LENGTHS (CUT TO SIZE). EXCLUDES ITEMS NOT HAVING RATED ELECTRICAL CHARACTERISTICS. ALSO EXCLUDES BUSHING, SLEEVE; CABLE NIPPLE, ELECTRICAL; CONDUIT (AS MODIFIED); INSULATION SLEEVING, ELECTRICAL, SPECIAL PURPOSE; INSULATION SLEEVING, THERMAL; SLEEVE, MARKER, CABLE; SLEEVING, TEXTILE, ELECTRICAL; TUBING, GLASS; AND TUBING, NONMETALLIC.
CAGE Information
Code | Company |
---|---|
81349 | MILITARY SPECIFICATIONS PROMULGATED |
Federal Supply Class
Title
ELECTRICAL INSULATORS AND INSULA
Inclusions:
INCLUDES TUBE, KNOB, CLEAT, STRAIN, AND STANDOFF INSULATORS; FEED THRU INSULATORS; BEAD INSULATORS; VARNISH CAMBRIC TAPE; FRICTION TAPE.
Exclusions:
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
HUES | COLOR | NATURAL |
ADZC | ENVIRONMENTAL PROTECTION | FLAME RESISTANT |
FLEX | FLEXIBILITY | FLEXIBLE |
ABHP | OVERALL LENGTH | ANY ACCEPTABLE |
AARX | INSIDE DIAMETER | 1.000 INCHES MINIMUM AND 1.036 INCHES MAXIMUM |
ADYY | COATING MATERIAL | PLASTIC,ACRYLIC |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
AAGT | WALL THICKNESS | 0.075 INCHES MAXIMUM |
ZZZK | SPECIFICATION/STANDARD DATA | 81349-MIL-I-3190/3 GOVERNMENT SPECIFICATION |
ABJH | TEMP RATING | 155.0 DEG CELSIUS |
STYL | STYLE DESIGNATOR | NONSHRINKABLE |
MATL | MATERIAL | FIBERGLASS, MIL-I-3190/3, CLASS 155, TYPE A, CATEGORY A |