Part Number
Part Number:
NSN:
NIIN:
Item Name:
CIRCUIT BREAKER
Definition:
A DEVICE WITH MEANS OTHER THAN FUSES FOR AUTOMATICALLY OPENING THE CIRCUIT IN WHICH IT IS INSTALLED WHEN THE CURRENT VARIES FROM THE PREDETERMINED VALUE FOR WHICH THE DEVICE IS SET. MAY INCLUDE PROVISIONS FOR MANUAL OPERATION. AT LEAST ONE SET OF CONTACTS MUST BE IN SERIES WITH THE ACTUATING ELEMENT(S). A COMBINATION OF SEMICONDUCTOR AND PASSIVE DEVICES MAY BE USED IN LIEU OF CONTACTS. FOR AUTOMATICALLY OPERATED ITEMS IN WHICH THE ACTUATING (TRIPPING) ELEMENT AND CONTACTS ARE NOT IN SERIES, SEE RELAY (AS MODIFIED). FOR ITEMS WHICH ARE OPERATED BOTH MANUALLY AND AUTOMATICALLY BUT THE ACTUATING ELEMENTS AND CONTACT ARE NOT IN SERIES, SEE RELAY-SWITCH. EXCLUDES CIRCUIT BREAKER BOX AND MAGNETO "BREAKER" ASSEMBLIES. SEE ALSO SWITCH (AS MODIFIED); AND CONTROLLER.
CAGE Information
Code |
Company |
81349 |
MILITARY SPECIFICATIONS PROMULGATED |
Characteristics (Decoded)
MRC |
Requirements Statement |
Clear Text Reply |
CPSM |
INTERNAL TRIP RELEASE CONFIGURATION |
SERIES TRIP ALL LOCATIONS |
FREQ |
FREQUENCY IN HERTZ |
60.0 ALL LOCATIONS |
AJWX |
MOUNTING SURFACE TO TERMINAL END DISTANCE |
1.828 INCHES MAXIMUM |
AXHR |
MOUNTING FACILITY TYPE AND QUANTITY |
1 THREADED BUSHING |
AKPX |
POLE QUANTITY |
3 |
AAQL |
BODY STYLE |
SINGLE POLE TYPE |
THSD |
THREAD SERIES DESIGNATOR |
UNEF |
ABXD |
BUSHING LENGTH |
0.332 INCHES MINIMUM AND 0.380 INCHES MAXIMUM |
CPRR |
MAIN CONTACT TRIPPING MECHANISM TYPE |
TRIP FREE |
CQJX |
NOMINAL THREAD SIZE |
0.375 INCHES |
CPRL |
TRIP RELEASE CHARACTERISTIC |
TIME DELAY ALL LOCATIONS |
CPRF |
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS |
240.0 AC ALL LOCATIONS AND 50.0 DC ALL LOCATIONS |
CPRQ |
RESET METHOD |
MANUAL |
CPRJ |
TRIP RELEASE METHOD |
MAGNETIC ALL LOCATIONS |
CPRW |
ACTUATOR FUNCTION |
TRIP-RESET |
CQXF |
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED |
HERMETICALLY SEALED |
ADAQ |
BODY LENGTH |
1.937 INCHES MAXIMUM |
ADAT |
BODY WIDTH |
1.562 INCHES MAXIMUM |
ADTV |
CASE MATERIAL |
METAL |
CBBL |
FEATURES PROVIDED |
HIGH INRUSH PROTECTION |
CPRH |
CIRCUIT PROTECTION TYPE |
OVERCURRENT ALL LOCATIONS |
ZZZK |
SPECIFICATION/STANDARD DATA |
81349-MIL-C-39019/6 GOVERNMENT SPECIFICATION |
TEST |
TEST DATA DOCUMENT |
81349-MIL-C-39019 SPECIFICATION |
CPLM |
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE |
0.5 AMPERES DC ALL LOCATIONS |
CPRT |
MANUAL ACTUATOR TYPE AND QUANTITY |
1 TOGGLE |
CMLP |
THREAD QUANTITY PER INCH |
32 |
AEBP |
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH |
0.906 INCHES MAXIMUM |
TTQY |
TERMINAL TYPE AND QUANTITY |
6 WIRE HOOK |