TRANSFORMER , POWER

Definition:

A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.

CAGE Information

Code Company
50655 QUALIMETRICS INC

Federal Supply Class

Title

COILS AND TRANSFORMERS

Inclusions:

INCLUDES COILS, EXCEPT IGNITION AND MAGNETO; COIL ASSEMBLIES; REACTORS; TRANSFORMERS.

Exclusions:

Characteristics (Decoded)

MRC Requirements Statement Clear Text Reply
TTQY TERMINAL TYPE AND QUANTITY 10 PIN
PKWT UNPACKAGED UNIT WEIGHT (NON-CORE) 0.750 POUNDS
ABMK OVERALL WIDTH 2.250 INCHES NOMINAL
CBME CUBIC MEASURE (NON-CORE) 5.7 CUBIC INCHES
CQLC WINDING TAP LOCATION (NON-CORE) CENTER TAP SINGLE COMPONENT ALL SECONDARY
AARG RELIABILITY INDICATOR NOT ESTABLISHED
CWJS WINDING OPERATING VOLTAGE 5.00 DC POUNDS PER HOUR WET SINGLE COMPONENT 1ST SECONDARY
ACZB FREQUENCY RATING 50.0 HERTZ NOMINAL SINGLE COMPONENT OR 60.0 HERTZ NOMINAL SINGLE COMPONENT
BPLC WINDING FUNCTION AND QUANTITY 2 PRIMARY SINGLE COMPONENT AND 2 SECONDARY SINGLE COMPONENT
CWJS WINDING OPERATING VOLTAGE 15.00 DC POUNDS PER HOUR WET SINGLE COMPONENT 2ND SECONDARY
ABHP OVERALL LENGTH 1.625 INCHES NOMINAL
CRBZ WINDING OPERATING CURRENT 130.0 MILLIAMPERES MAXIMUM OF STANDARD RANGE B SINGLE COMPONENT 2ND SECONDARY
ABKW OVERALL HEIGHT 1.563 INCHES NOMINAL
CRBZ WINDING OPERATING CURRENT 835.0 MILLIAMPERES MAXIMUM OF STANDARD RANGE B SINGLE COMPONENT 1ST SECONDARY
ACZC INPUT-OUTPUT PHASE RELATIONSHIP SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
CWJS WINDING OPERATING VOLTAGE 115.00 AC POUNDS PER HOUR WET SINGLE COMPONENT ALL PRIMARY
AXGY MOUNTING METHOD TERMINAL SINGLE GROUP
AKNA INCLOSURE TYPE PARTIALLY INCLOSED