Part Number
Part Number:
NSN:
NIIN:
Item Name:
RELAY , ELECTROMAGNETIC
Definition:
A RELAY WHICH IS ACTUATED BY THE EFFECT OF A MAGNETIC FIELD DEVELOPED BY THE CURRENT IN ITS ENERGIZING COIL(S). INCLUDES SOLENOID AND ARMATURE TYPES. EXCLUDES CONTACTOR, MAGNETIC; RELAY, METER MOVEMENT; RELAY, MOTOR DRIVEN; RELAY, REED; RELAY, RESONANT REED; RELAY, ROTARY; AND SWITCH, STEPPING.
CAGE Information
Code | Company |
---|---|
81349 | MILITARY SPECIFICATIONS PROMULGATED |
Federal Supply Class
Title
RELAYS AND SOLENOIDS
Inclusions:
INCLUDES ELECTROMAGNETIC ACTUATORS.
Exclusions:
EXCLUDES CONTRACTORS.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
CWAB | MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 28.0 DC |
AKDX | WINDING QUANTITY | 1 |
AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.156 INCHES NOMINAL SINGLE MOUNTING FACILITY |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.375 INCHES NOMINAL SINGLE MOUNTING FACILITY |
TTQY | TERMINAL TYPE AND QUANTITY | 5 THREADED STUD ALL FUNCTIONS |
TEST | TEST DATA DOCUMENT | 81349-MIL-PRF-6106 SPECIFICATION |
APCN | COIL QUANTITY | 1 |
CBBL | FEATURES PROVIDED | COIL VOLTAGE SUPPRESSION AND POLARIZED |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 0.625 INCHES NOMINAL SINGLE MOUNTING FACILITY |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 2 UNTHREADED HOLE SINGLE MOUNTING FACILITY |
CRNG | NONPILE-UP MAIN CONTACT ARRANGEMENT | 1 POLE, DOUBLE THROW, DOUBLE BREAK/DOUBLE MAKE, PERMANENT JUMPER, ONE POSITION MOMENTARY |
ZZZK | SPECIFICATION/STANDARD DATA | 81349-MIL-PRF-6106/15 GOVERNMENT SPECIFICATION |
ADZC | ENVIRONMENTAL PROTECTION | HERMETIC |
APNP | DUTY TYPE | CONTINUOUS |
ABKW | OVERALL HEIGHT | 2.385 INCHES MAXIMUM |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 55.0 AMPERES DC INDUCTIVE LOAD |
ABHP | OVERALL LENGTH | 2.810 INCHES NOMINAL |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 55.0 AMPERES DC LAMP LOAD |
CQYJ | MOUNTING FACILITY PATTERN | IN-LINE SINGLE MOUNTING FACILITY |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 55.0 AMPERES DC MOTOR LOAD |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 55.0 AMPERES DC RESISTIVE LOAD |
CSXF | OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 28.0 VOLTS TEARDROP, TWO HOLES TYPE 4F SINGLE WINDING |
ABMK | OVERALL WIDTH | 1.100 INCHES NOMINAL |