Part Number
Part Number:
NSN:
NIIN:
Item Name:
RELAY , ELECTROMAGNETIC
Definition:
A RELAY WHICH IS ACTUATED BY THE EFFECT OF A MAGNETIC FIELD DEVELOPED BY THE CURRENT IN ITS ENERGIZING COIL(S). INCLUDES SOLENOID AND ARMATURE TYPES. EXCLUDES CONTACTOR, MAGNETIC; RELAY, METER MOVEMENT; RELAY, MOTOR DRIVEN; RELAY, REED; RELAY, RESONANT REED; RELAY, ROTARY; AND SWITCH, STEPPING.
CAGE Information
Code | Company |
---|---|
81349 | MILITARY SPECIFICATIONS PROMULGATED |
Federal Supply Class
Title
RELAYS AND SOLENOIDS
Inclusions:
INCLUDES ELECTROMAGNETIC ACTUATORS.
Exclusions:
EXCLUDES CONTRACTORS.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
ZZZK | SPECIFICATION/STANDARD DATA | 81349--83536/1-026M GOVERNMENT SPECIFICATION |
AKDX | WINDING QUANTITY | 1 |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 1.0 AMPERES AC LAMP LOAD AND 1.0 AMPERES DC LAMP LOAD |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 3.0 AMPERES AC INDUCTIVE LOAD AND 3.0 AMPERES DC INDUCTIVE LOAD |
TTQY | TERMINAL TYPE AND QUANTITY | 8 WIRE HOOK ALL FUNCTIONS |
TEST | TEST DATA DOCUMENT | 81349-MIL-R-83536 SPECIFICATION |
APCN | COIL QUANTITY | 1 |
CRPQ | NOMINAL OPERATING CURRENT RATING AND TYPE | 65.0 MILLIAMPERES DC SINGLE WINDING |
ABTD | MOUNTING SLOT WIDTH | 0.123 INCHES MINIMUM SINGLE MOUNTING FACILITY AND 0.143 INCHES MAXIMUM SINGLE MOUNTING FACILITY |
ABKW | OVERALL HEIGHT | 0.620 INCHES MINIMUM AND 0.640 INCHES MAXIMUM |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 2 SLOTTED HOLE SINGLE MOUNTING FACILITY |
FEAT | SPECIAL FEATURES | FAILURE RATE EQUALS 1.0 PERCENT |
AGAV | END ITEM IDENTIFICATION | F-16ADFRADAR |
CWAB | MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 200.0 AC AND 28.0 DC |
APNA | WINDING DC RESISTANCE RATING | 500.0 OHMS NOMINAL SINGLE WINDING |
APNP | DUTY TYPE | CONTINUOUS |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 2.0 AMPERES AC MOTOR LOAD AND 2.0 AMPERES DC MOTOR LOAD |
ABHP | OVERALL LENGTH | 1.260 INCHES MINIMUM AND 1.280 INCHES MAXIMUM |
CRNG | NONPILE-UP MAIN CONTACT ARRANGEMENT | 2 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 5.0 AMPERES AC RESISTIVE LOAD AND 5.0 AMPERES DC RESISTIVE LOAD |
CQYJ | MOUNTING FACILITY PATTERN | IN-LINE SINGLE MOUNTING FACILITY |
CRTL | CRITICALITY CODE JUSTIFICATION | FEAT |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 1.062 INCHES MINIMUM SINGLE MOUNTING FACILITY AND 1.078 INCHES MAXIMUM SINGLE MOUNTING FACILITY |
ABMK | OVERALL WIDTH | 0.390 INCHES MINIMUM AND 0.410 INCHES MAXIMUM |
CSXF | OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 28.0 VOLTS TEARDROP, TWO HOLES TYPE 4F SINGLE WINDING |