Part Number
Definition:
A SPECIFIC ELECTRICAL ELEMENT OR SET OF ELECTRICAL ELEMENTS THAT ARE CONNECTED TOGETHER TO FORM A FIXED ARRANGEMENT AND USED AS A SUBSTITUTE LOAD FOR TERMINATING AN ELECTRICAL CIRCUIT. A DUMMY LOAD CONTAINS ALL THE ESSENTIAL ELECTRICAL CHARACTERISTICS NECESSARY TO TERMINATE THE CIRCUIT BUT DOES NOT FUNCTION IN THE SAME MANNER AS THE LOAD WHICH IT REPLACES. EXAMPLES ARE RESISTORS USED TO REPLACE ANTENNAS, BATTERIES, LOUDSPEAKERS, OR THE LIKE. INCLUDES SINGLE PORT TERMINATIONS OF TWIN LEAD, COAXIAL AND WAVEGUIDE TRANSMISSION LINES AS LOW POWER TERMINATIONS OF A SECTION OF A TRANSMISSION SYSTEM IN A SPECIFIED MANNER. INCLUDES DUMMY LOADS WHEN ARRANGED IN A GROUP OR BANK. EXCLUDES POWER ABSORBERS. SEE ALSO LOAD BANK, ELECTRICAL.
CAGE Information
Code | Company |
---|---|
96341 | COBHAM ELECTRONIC SYSTEMS INC. DBA C |
Federal Supply Class
Title
ANTENNAS, WAVEGUIDES, AND RELATE
Inclusions:
INCLUDES AERIALS; MASTS; TOWER EQUIPMENT; ATTENUATORS; COUPLERS; TRANSMISSION LINES.
Exclusions:
EXCLUDES TOWER STRUCTURES.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AFGQ | FREQUENCY RANGE RATING | +5.400/+5.900 GIGAHERTZ |
ARNH | OPERATING POSITION | ALL POSITIONS |
AKNK | VOLTAGE STANDING WAVE RATIO FREQUENCY RANGE | +5.400/+5.900 GIGAHERTZ |
ADAV | OVERALL DIAMETER | 3.125 INCHES NOMINAL |
BFMF | COOLING METHOD | SELF-COOLED |
AWNC | INTERNAL OPERATING PRESSURE | ANY ACCEPTABLE |
ADAT | BODY WIDTH | 1.625 INCHES MAXIMUM |
STYL | STYLE DESIGNATOR | WAVEGUIDE MOUNTED |
ACYW | IMPEDANCE RATING IN OHMS | NOT RATED |
ADAU | BODY HEIGHT | 0.875 INCHES MAXIMUM |
AKRZ | TERMINATION TYPE | WAVEGUIDE FLANGE |
AGAV | END ITEM IDENTIFICATION | RADAR SET AN/SPS-67(V)1 |
AKSA | WAVEGUIDE FLANGE DESIGNATION | UG-441/U |
ABHP | OVERALL LENGTH | 4.250 INCHES MAXIMUM |
AHTW | VOLTAGE STANDING WAVE RATIO | 1.10 |
AJDB | POWER RATING | 375.000 WATTS AVERAGE AND 300.000 KILOWATTS PEAK |