Part Number
Definition:
AN ELECTRICAL FITTING WITH ELECTRICAL CONTACTS CONSTRUCTED TO BE AFFIXED TO THE END OF A CABLE, CONDUIT, COAXIAL LINE, CORD, WIRE (INCLUDES PRINTED/ETCHED), PRINTED WIRING BOARD, OR THE LIKE FOR CONVENIENCE IN JOINING WITH ANOTHER ELECTRICAL CONNECTOR(S) OR PRINTED WIRING BOARD. IT IS DESIGNED TO BE MOUNTED ON A BULKHEAD, CHASSIS, PANEL, WALL, PRINTED WIRING BOARD, OR THE LIKE. EXCLUDES LAMPHOLDER; JACK, TELEPHONE; JACK, TIP; INSERT ELECTRICAL CONNECTOR; INSERT MODULE, ELECTRICAL CONNECTOR; CONNECTOR BODY (AS MODIFIED) AND SOCKET, PLUG-IN ELECTRONIC COMPONENTS. SEE ALSO WIRING HARNESS (AS MODIFIED) AND CABLE ASSEMBLY (AS MODIFIED). FOR ITEMS WITH TERMINATION WIRES OF MORE THAN FOUR INCHES IN LENGTH, SEE LEAD ASSEMBLY, ELECTRICAL. FOR ITEMS WITHOUT INSERTS, SEE SHELL, ELECTRICAL CONNECTOR.
CAGE Information
Code | Company |
---|---|
77820 | AMPHENOL CORPORATION DBA AMPHENOL AE |
Federal Supply Class
Title
CONNECTORS, ELECTRICAL
Inclusions:
INCLUDES PLUGS; JACKS; RECEPTACLES, ELECTRONIC COMPONENT SOCKETS AND ASSOCIATED ACCESSORIES
Exclusions:
EXCLUDES INTERCONNECTORS, FIBER OPTIC
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
ABKW | OVERALL HEIGHT | 1.250 INCHES NOMINAL |
CQYH | CONTACT SURFACE TREATMENT | GOLD SINGLE MATING END SINGLE CONTACT GROUPING AND NICKEL SINGLE MATING END SINGLE CONTACT GROUPING |
CXCG | INCLUDED CONTACT QUANTITY | 116 SINGLE MATING END SINGLE CONTACT GROUPING |
AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.122 INCHES MINIMUM AND 0.127 INCHES MAXIMUM |
PRMT | PRECIOUS MATERIAL | GOLD |
AFQW | MATING END QUANTITY | 1 |
AFRV | CONNECTOR LOCKING METHOD | FRICTION |
AAQL | BODY STYLE | STRAIGHT TYPE |
CTKL | INSERT MATERIAL DOCUMENT AND CLASSIFICATION | MIL-M-14,TY SDG-F OR TY GDI-30F MIL SPEC 1ST MATERIAL RESPONSE SINGLE MATING END AND MIL-M-14,TY SDG-F OR TY GDI-30F MIL SPEC 2ND MATERIAL RESPONSE SINGLE MATING END OR MIL-M-24519,TY GPT-30F OR GST-40F MIL SPEC 3RD MATERIAL RESPONSE SINGLE MATING END |
CRBJ | CONTACT SURFACE TREATMENT DOCUMENT AND CLASSIFICATION | MIL-G-45204,TY 2,CL 1,GR C MIL SPEC 1ST TREATMENT RESPONSE SINGLE MATING END SINGLE CONTACT GROUPING AND QQ-N-290,CL 2 FED SPEC 2ND TREATMENT RESPONSE SINGLE MATING END SINGLE CONTACT GROUPING |
ABHP | OVERALL LENGTH | 7.095 INCHES MAXIMUM |
PMLC | PRECIOUS MATERIAL AND LOCATION | CONTACT SURFACES GOLD |
CQZG | INSERT MATERIAL | PLASTIC DIALLYL PHTHALATE SINGLE MATING END AND GLASS FIBER SINGLE MATING END OR PLASTIC POLYESTER SINGLE MATING END |
CQTM | TERMINAL LOCATION | BACK SINGLE MATING END SINGLE CONTACT GROUPING |
PMWT | PRECIOUS MATERIAL AND WEIGHT | 0.116 GOLD GRAINS, TROY |
ZZZK | SPECIFICATION/STANDARD DATA | 81349-MIL-C-55302/167 GOVERNMENT SPECIFICATION |
ADZC | ENVIRONMENTAL PROTECTION | SHOCK RESISTANT AND HUMIDITY RESISTANT AND CORROSION RESISTANT AND VIBRATION RESISTANT AND FUNGUS RESISTANT |
CSGF | CONTACT MATERIAL DOCUMENT AND CLASSIFICATION | QQ-B-750 FED SPEC SINGLE MATERIAL RESPONSE SINGLE MATING END SINGLE CONTACT GROUPING OR QQ-B-626 FED SPEC SINGLE MATERIAL RESPONSE SINGLE MATING END SINGLE CONTACT GROUPING OR QQ-C-530 FED SPEC SINGLE MATERIAL RESPONSE SINGLE MATING END SINGLE CONTACT GROUPING |
AFQX | CONTACT POSITION ARRANGEMENT STYLE | 2 ROWS OF CONTACTS NON-INSERTED BOARD SINGLE MATING END |
CQTZ | CONTACT MATERIAL | COPPER ALLOY SINGLE MATING END SINGLE CONTACT GROUPING |
ABMK | OVERALL WIDTH | 0.390 INCHES MAXIMUM |
AEJN | DISTANCE BETWEEN MOUNTING FACILITY CENTERS | 6.775 INCHES NOMINAL |
AFQZ | CONTACT REMOVABILITY | NONREMOVABLE SINGLE MATING END SINGLE CONTACT GROUPING |
CSCF | TERMINAL TYPE | PIN SINGLE MATING END SINGLE CONTACT GROUPING |
TEST | TEST DATA DOCUMENT | 81349-MIL-C-55302 SPECIFICATION |
AFRC | CONTACT MAXIMUM CURRENT RATING IN AMPS | 3.0 SINGLE MATING END SINGLE CONTACT GROUPING |
AFRN | POLARIZATION METHOD | MATING END |