Part Number
Definition:
AN ITEM CONSISTING OF A PARTIAL TURN AS ONE OR MORE TURNS OF WIRE OR OTHER CONDUCTIVE MATERIAL WHICH CONSTITUTES ONE CONTINUOUS UNTAPPED WINDING. IT MAY BE WOUND OR FORMED IN OTHER THAN A CIRCULAR MANNER AND MAY BE SELF-SUPPORTING, REQUIRING NO COIL FORM. IT IS SPECIFICALLY DESIGNED TO FURNISH INDUCTIVE REACTANCE IN A CIRCUIT CARRYING RADIO FREQUENCY CURRENT RANGING FROM 20 KILOHERTZ (KILOCYCLES) AND ABOVE. IT MAY INCLUDE TUNING DEVICES, INTEGRAL RESISTORS AND CAPACITORS; HOWEVER, EXCLUDES FILTER (AS MODIFIED). THE COIL HAS ONLY TWO ELECTRICAL TERMINALS. FOR ITEMS HAVING TAPPED WINDING OR MORE THAN ONE WINDING - SEE TRANSFORMER, RADIO FREQUENCY. FOR COILS WOUND ON RESISTORS, WHICH ARE DESIGNED TO BE INSERTED IN THE CIRCUIT OF A RADIO FREQUENCY STAGE TO SUPPRESS HIGH FREQUENCY PARASITIC OSCILLATIONS, SEE SUPPRESSOR, PARASITIC.
CAGE Information
Code | Company |
---|---|
81349 | MILITARY SPECIFICATIONS PROMULGATED |
Federal Supply Class
Title
COILS AND TRANSFORMERS
Inclusions:
INCLUDES COILS, EXCEPT IGNITION AND MAGNETO; COIL ASSEMBLIES; REACTORS; TRANSFORMERS.
Exclusions:
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
CRGS | DC RESISTANCE RATING IN OHMS | 0.220 SINGLE COMPONENT SINGLE WINDING |
CRBZ | WINDING OPERATING CURRENT | 815.0 MILLIAMPERES MAXIMUM OF STANDARD RANGE B SINGLE COMPONENT SINGLE WINDING |
TTQY | TERMINAL TYPE AND QUANTITY | 2 WIRE LEAD |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
ZZZK | SPECIFICATION/STANDARD DATA | 81349-MIL-C-39010/8 GOVERNMENT SPECIFICATION |
AEHZ | MAXIMUM OPERATING TEMP | 125.0 DEG CELSIUS |
ACZP | COIL FORM TYPE | SOLID SINGLE COMPONENT |
AARG | RELIABILITY INDICATOR | ESTABLISHED |
AFGS | MINIMUM SELF-RESONANT FREQUENCY (NON-CORE) | 410.0 MEGAHERTZ SINGLE COMPONENT |
TEST | TEST DATA DOCUMENT | 81349-MIL-C-39010 SPECIFICATION |
PKWT | UNPACKAGED UNIT WEIGHT (NON-CORE) | 0.3 GRAMS |
BKPL | RATING METHOD | ELECTRICAL SINGLE COMPONENT SINGLE WINDING |
ACZR | CORE CONSTRUCTION | S0LID SINGLE COMPONENT |
ADAQ | BODY LENGTH | 0.240 INCHES MINIMUM AND 0.260 INCHES MAXIMUM |
CRHJ | QUALITY FACTOR | 30 MINIMUM SINGLE COMPONENT SINGLE WINDING |
AARH | RELIABILITY FAILURE RATE LEVEL IN PERCENT | 0.100 |
ACYV | INDUCTANCE RATING | 0.33 MICROHENRIES NOMINAL SINGLE COMPONENT SINGLE WINDING |
CRLC | FREQUENCY AT WHICH INDUCTANCE AND QUALITY FACTOR APPLIES (NON-CORE) | 25.0 MEGAHERTZ SINGLE COMPONENT SINGLE WINDING |
ADAV | OVERALL DIAMETER | 0.085 INCHES MINIMUM AND 0.105 INCHES MAXIMUM |
AXGY | MOUNTING METHOD | TERMINAL SINGLE GROUP |