Part Number
Part Number:
NSN:
NIIN:
Item Name:
BLOOD RECIPIENT SET , INDIRECT TRA
Definition:
AN ITEM USED FOR ACCURATE ADMINISTRATION OF BLOOD OR BLOOD DERIVATIVES IN CONTROLLED VOLUME FROM BLOOD BOTTLES AND STANDARD BLOOD BAGS. IT IS EQUIPPED WITH FILTER CHAMBER TO PREVENT PASSAGE OF CLOTS OR FIBRIN. IT MAY ALSO BE USED FOR ADMINISTRATION OF INTRAVENOUS SOLUTIONS. FOR SIMILAR ITEMS WITHOUT A BLOOD FILTER, SEE INTRAVENOUS INJECTION SET.
CAGE Information
Code | Company |
---|---|
81349 | MILITARY SPECIFICATIONS PROMULGATED |
Federal Supply Class
Title
MEDICAL AND SURGICAL INSTRUMENTS
Inclusions:
INCLUDES ANESTHESIA APPARATUS; BLOOD TRANSFUSION APPARATUS; OXYGEN THERAPY APPARATUS; RESPIRATORS; ORTHOPEDIC SUPPLIES; ARCH SUPPORTS; CLINICAL THERMOMETERS; SUTURES; HEARING AIDS; VETERINARY EQUIPMENT; ENDOSCOPES, FIBER OPTIC.
Exclusions:
EXCLUDES OPTHALMIC INSTRUMENTS, EQUIPMENT, AND SUPPLIES; NON-MEDICAL ENDOSCOPES.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AJJZ | DOCUMENT TYPE | MILITARY SPECIFICATION |
FEAT | SPECIAL FEATURES | DW/GRADUATED METERING CHAMBER; DISPOSABLE; STERILE FLUID PATH W/O NEEDLE; C/O PIERCING DEVICE; PLASTIC TUBING,MEDICINAL ENTRY ASSY; W/IN-LINE METERING CHAMBER GRADUATED AT 10 ML INTERVALS FROM 0 TO 100 ML,INDICATING BOTH VOL CONTAINED AND VOL DELIVERED,FILTER HOUSING W/NYLON MESH FILTER,MOLDED RUBBER TUBING-TO-NEEDLE ADAPTER,2 FLOW CONTROL CLAMPS,NEEDLE ADAPTER AND END PROTECTORS; FOR INDIRECT TRANSFUSION OF WHOLE BLOOD AND ADMIN OF BLOOD DERIVATIVES; FOR USE W/VACUUM BLOOD BOTTLE,OR BLOOD COLLECTING-DISPENSING BAG AND DONOR SET,6515-00-079-9483,6515-00-079-9510,6515-01-075-4021,6515-01-076-1780,6515-01-042-4167 AND 6515-01-107-2636; FOR WARMING TUBES,ORDER 6515-00-926-2205; FOR BLOOD TRANSFUSION FILTER,ORDER 6515-01-082-4900; FOR INFUSOR,ORDER 6515-00-584-2893; INDIVIDUALLY SEALED; NOTE: THIS ITEM SHOULD NOT BE USED IN CRTL APPL WHERE INFUSION VOL MUST BE CONTROLLED WITHIN A FEW MM; NOTE: BLOOD RECIPIENT SETS SHOULD NOT BE USED FOR PLATELET INFUSIONS |
SUCB | UNIT OF ISSUE CUBE | 0.026 CUBIC FEET |
SUWT | UNIT OF ISSUE WEIGHT | 0.19 POUNDS |
EXME | EXTERIOR CONTAINER CUBIC MEASURE | 2.486 CUBIC FEET |
AJJW | COMPONENT QUANTITY | 13 |
AJJX | COMPONENT DOCUMENT ORIGIN | GOVERNMENT |
PKQT | INTERMEDIATE PACKAGE QUANTITY | 12 |
AJJY | DOCUMENT SOURCE | 81349 |
ECWT | EXTERIOR CONTAINER WEIGHT | 18.000 POUNDS |
CXCY | PART NAME ASSIGNED BY CONTROLLING AGENCY | BLOOD RECIPIENT SET INDIRECT TRANSFUSION 13 COMP STERILE DISP |
EXQT | EXTERIOR CONTAINER QUANTITY | 96 |
AYDR | DOCUMENT IDENTIFICATION | MIL-B-36646 |