PUMP UNIT , ROTARY
Definition:
AN ASSEMBLED UNIT CONSISTING OF A COMMONLY MOUNTED ROTARY PUMP(S), PRIME MOVER(S), AND THE NECESSARY COMPONENTS TO PROVIDE FOR A COMPLETE OPERATION.
CAGE Information
Code | Company |
---|---|
81349 | MILITARY SPECIFICATIONS PROMULGATED |
Federal Supply Class
Title
POWER AND HAND PUMPS
Inclusions:
Exclusions:
EXCLUDES LABORATORY JET PUMPS (FSG 65 AND 66).
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
CSYL | PRIME MOVER POWER RATING | 2.000 HORSEPOWER |
CSYL | PRIME MOVER POWER RATING | 2.000 HORSEPOWER |
FREQ | FREQUENCY IN HERTZ | 60.0 |
ADZC | ENVIRONMENTAL PROTECTION | SPLASH PROOF |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
AHYV | MAXIMUM DISCHARGE FLOW RATE | 25.0 GALLONS PER MINUTE |
AAXS | PRIME MOVER COOLING MEDIUM | AIR |
ZZZT | NONDEFINITIVE SPEC/STD DATA | X TYPE AND N2 CLASS |
AENC | PUMP QUANTITY | 1 |
AMPS | CURRENT RATING IN AMPS | 2.8 |
AHYW | DISCHARGE PRESSURE | 50.0 POUNDS PER SQUARE INCH GAGE |
AKDJ | PRIME MOVER TYPE | ELECTRIC MOTOR |
FAAZ | PHASE | THREE |
ZZZX | DEPARTURE FROM CITED DESIGNATOR (NON-CORE) | AS MODIFIED BY BLACKMER PUMP DIV DWG NO. E3428 |
AHZR | ROTARY PUMP DESIGN | VANE |
AAYU | INTAKE CONNECTION TYPE | ROUND FLANGE |
AHZA | PUMPING ELEMENT OPERATING POSITION | VERTICAL |
AAYT | INTAKE CONNECTION QUANTITY | 1 |
AENK | COOLING METHOD | AIR TO AIR COOLED |
ACKL | MEDIA FOR WHICH DESIGNED | HYDROCARBON FUELS AND OILS |
AAXH | PRIME MOVER QUANTITY | 1 |
AAYW | DISCHARGE CONNECTION TYPE | ROUND FLANGE |
AAYV | DISCHARGE CONNECTION QUANTITY | 1 |
AHYZ | OPERATING SPEED AT RATED CAPACITY | 350.0 REVOLUTIONS PER MINUTE |
ACDC | CURRENT TYPE | AC |
ELEC | VOLTAGE IN VOLTS | 440.0 |