Part Number
Definition:
AN ITEM CONSISTING OF INSULATING MATERIAL, WHICH IS SPECIFICALLY DESIGNED TO HAVE FASTENED THEREON, OR ON WHICH ARE FASTENED TERMINAL(S), SUCH AS SCREWS, SOLDER LUGS, SOLDER STUDS, SOLDERLESS CONNECTORS, CLIPS, AND THE LIKE. IT IS USUALLY USED FOR JUNCTIONS OR TERMINATIONS OF WIRE OR CABLE ASSEMBLIES. IT DOES NOT INCLUDE ITEMS AS DEFINED ABOVE WITH PARTS, SUCH AS RESISTORS AND CAPACITORS MOUNTED THEREON. DO NOT USE IF A MORE SPECIFIC NAME EXISTS, SUCH AS FUSEHOLDER; HOLDER, RESISTOR; FANNING STRIP; CONTACT ASSEMBLY, ELECTRICAL; JACK ASSEMBLY, TIP; CHAMBER, CABLE TERMINAL; PANEL (2) (AS MODIFIED); CONNECTOR (AS MODIFIED). EXCLUDES TERMINAL, STUD; TERMINAL, FEEDTHRU, INSULATED; POST, BINDING, ELECTRICAL; AND CHASSIS, ELECTRICAL-ELECTRONIC EQUIPMENT. FOR ITEMS HAVING PRINTED ELECTRICAL CONDUCTOR PATHS, SEE PRINTED WIRING BOARD.
CAGE Information
Code | Company |
---|---|
81349 | MILITARY SPECIFICATIONS PROMULGATED |
Federal Supply Class
Title
LUGS, TERMINALS, AND TERMINAL ST
Inclusions:
INCLUDES BINDING POSTS; BATTERY CLIPS; STUD TERMINALS; TEST CLIPS.
Exclusions:
EXCLUDES CAPS, ELECTRICAL; CLIPS, ELECTRICAL; AND CONTACTS, ELECTRICAL.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
CQCZ | TERMINAL CONNECTING LINK QUANTITY | 4 SINGLE |
MATT | MATERIAL | PLASTIC BOARD |
AAPB | DIELECTRIC WITHSTANDING VOLTAGE IN VOLTS | 2.2 |
AAQW | MOUNTING SLOT LENGTH | 0.281 INCHES |
ABGR | BOARD HEIGHT EXCLUDING TERMINALS | 0.781 INCHES |
CWLN | TERMINAL DESIGN | LINKED NONFEEDTHRU |
ABCU | DISTANCE BETWEEN TERMINAL ROW CENTERS | 0.812 INCHES |
AMPS | CURRENT RATING IN AMPS | 40.0 |
ABCS | TERMINAL ROW QUANTITY | 2 |
AAQX | MOUNTING SLOT WIDTH | 0.219 INCHES |
ABGN | BOARD OVERALL LENGTH | 3.375 INCHES |
CWLG | TERMINAL PATTERN ARRANGEMENT | MULTI-ROW |
CSCR | TERMINAL CONNECTING LINK TYPE | 1 SINGLE |
CSCS | NONFEEDTHRU TERMINAL QUANTITY | 4 SINGLE |
ABCT | CENTER TO CENTER DISTANCE BETWEEN TERMINALS | 0.531 INCHES |
ABDX | DISTANCE FROM LEFT EDGE OF TERMINAL BOARD TO CENTER OF FIRST MOUNTING FACILITY | 0.250 INCHES |
ABGS | BASE THICKNESS | 0.375 INCHES |
ABDW | DISTANCE FROM BOTTOM EDGE OF TERMINAL BOARD TO CENTER OF MOUNTING HOLE | 0.906 INCHES |
MATT | MATERIAL | COPPER ALLOY TERMINALS |
ABDU | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.875 INCHES |
ABGQ | BOARD OVERALL HEIGHT | 0.844 INCHES |
ABCX | BOARD CONSTRUCTION | HOLLOW CONSTRUCTION WITHOUT INSULATED STRIP |
CRNL | NONFEEDTHRU TERMINAL TYPE | 598 SINGLE |
ABGP | BOARD OVERALL WIDTH | 1.812 INCHES |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 2 SLOT |
AAQL | BODY STYLE | BARRIER TYPE |