Follow Us on Google+

Request A Price Quote:

Part Number

Part Number:
NSN:
NIIN:
Item Name:
CIRCUIT BREAKER

Definition:

A DEVICE WITH MEANS OTHER THAN FUSES FOR AUTOMATICALLY OPENING THE CIRCUIT IN WHICH IT IS INSTALLED WHEN THE CURRENT VARIES FROM THE PREDETERMINED VALUE FOR WHICH THE DEVICE IS SET. MAY INCLUDE PROVISIONS FOR MANUAL OPERATION. AT LEAST ONE SET OF CONTACTS MUST BE IN SERIES WITH THE ACTUATING ELEMENT(S). A COMBINATION OF SEMICONDUCTOR AND PASSIVE DEVICES MAY BE USED IN LIEU OF CONTACTS. FOR AUTOMATICALLY OPERATED ITEMS IN WHICH THE ACTUATING (TRIPPING) ELEMENT AND CONTACTS ARE NOT IN SERIES, SEE RELAY (AS MODIFIED). FOR ITEMS WHICH ARE OPERATED BOTH MANUALLY AND AUTOMATICALLY BUT THE ACTUATING ELEMENTS AND CONTACT ARE NOT IN SERIES, SEE RELAY-SWITCH. EXCLUDES CIRCUIT BREAKER BOX AND MAGNETO "BREAKER" ASSEMBLIES. SEE ALSO SWITCH (AS MODIFIED); AND CONTROLLER.

CAGE Information

Code Company
96906 MILITARY STANDARDS PROMULGATED BY MI

Federal Supply Class

Title

CIRCUIT BREAKERS

Inclusions:

INCLUDES CIRCUIT BREAKERS AND CUTOUTS.

Exclusions:

EXCLUDES RELAYS.

Characteristics (Decoded)

MRC Requirements Statement Clear Text Reply
BBRG STORAGE TYPE GENERAL PURPOSE WAREHOUSE
CPRH CIRCUIT PROTECTION TYPE OVERCURRENT SINGLE LOCATION
CQXF INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED EXPLOSION PROOF AND CORROSION RESISTANT
CPRN ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT 138.0 SINGLE LOCATION
AAQL BODY STYLE SINGLE POLE TYPE
AEBP CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH 1.183 INCHES MINIMUM AND 1.193 INCHES MAXIMUM
AFJN FRAGILITY FACTOR MODERATELY RUGGED
CPRR MAIN CONTACT TRIPPING MECHANISM TYPE NONTRIP FREE
TEST TEST DATA DOCUMENT 81349-MIL-C-7079 SPECIFICATION
ABXD BUSHING LENGTH 0.141 INCHES MINIMUM AND 0.251 INCHES MAXIMUM
CPSM INTERNAL TRIP RELEASE CONFIGURATION SERIES TRIP SINGLE LOCATION
TTQY TERMINAL TYPE AND QUANTITY 2 TAB W/SCREW
AJWX MOUNTING SURFACE TO TERMINAL END DISTANCE 2.000 INCHES MAXIMUM
ADAQ BODY LENGTH 2.189 INCHES MAXIMUM
CPLM MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE 25.0 AMPERES DC SINGLE LOCATION
ADTV CASE MATERIAL PLASTIC
AKPX POLE QUANTITY 1
CPRQ RESET METHOD MANUAL
PKWT UNPACKAGED UNIT WEIGHT 0.200 POUNDS
AEBY DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH 1.796 INCHES MINIMUM AND 1.828 INCHES MAXIMUM
AXHR MOUNTING FACILITY TYPE AND QUANTITY 2 THREADED HOLE
THSD THREAD SERIES DESIGNATOR UNC
CPRJ TRIP RELEASE METHOD THERMAL SINGLE LOCATION
ZZZK SPECIFICATION/STANDARD DATA 96906-MS24506 GOVERNMENT STANDARD
CQWN TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT 10.000 MINIMUM AT 200 PCT SINGLE LOCATION AND 50.000 MAXIMUM AT 200 PCT SINGLE LOCATION
CPRT MANUAL ACTUATOR TYPE AND QUANTITY 1 PUSH-PULL
CPRW ACTUATOR FUNCTION TRIP-RESET
CPRX ACTUATOR POSITION DESIGNATION AT POLE ONE
CPRF OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS 28.0 DC SINGLE LOCATION
ADAT BODY WIDTH 0.750 INCHES MAXIMUM
CMLP THREAD QUANTITY PER INCH 32
CPRL TRIP RELEASE CHARACTERISTIC TIME DELAY SINGLE LOCATION
CRCF TRIP RELEASE AMBIENT TEMP RATING 25.0 DEG CELSIUS NOMINAL SINGLE LOCATION
CQJX NOMINAL THREAD SIZE 0.138 INCHES
CPRG MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS 3000.0 DC SINGLE LOCATION

Similar Parts

MS24506-25 , MS2450625 , 5925-00-805-3653 , 5925008053653 , 008053653