Part Number
Definition:
AN ELECTRICAL FITTING WITH ELECTRICAL CONTACTS, CONSTRUCTED TO BE AFFIXED TO THE END OF A CABLE, CONDUIT, COAXIAL LINE, CORD OR WIRING FOR CONVENIENCE IN JOINING WITH OTHER ELECTRICAL CONNECTOR(S) OR PRINTED WIRING BOARD AND IS NOT DESIGNED TO BE MOUNTED ON A BULKHEAD, CHASSES, PANEL, PRINTED WIRING BOARD, OR THE LIKE. EXCLUDES JACK, TELEPHONE; JACK, TIP; PLUG, TELEPHONE; PLUG TIP; INSERT, ELECTRICAL CONNECTOR; CONNECTOR BODY (AS MODIFIED); AND SOCKET, PLUG-IN, ELECTRONIC COMPONENTS. SEE ALSO LEAD ASSEMBLY, ELECTRICAL; WIRING HARNESS (AS MODIFIED); AND CABLE ASSEMBLY (AS MODIFIED). FOR ITEMS WITHOUT INSERTS, SEE SHELL, ELECTRICAL CONNECTOR.
CAGE Information
Code | Company |
---|---|
96906 | MILITARY STANDARDS PROMULGATED BY MI |
Federal Supply Class
Title
CONNECTORS, ELECTRICAL
Inclusions:
INCLUDES PLUGS; JACKS; RECEPTACLES, ELECTRONIC COMPONENT SOCKETS AND ASSOCIATED ACCESSORIES
Exclusions:
EXCLUDES INTERCONNECTORS, FIBER OPTIC
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AFQX | CONTACT POSITION ARRANGEMENT STYLE | 14S-5 SINGLE MATING END |
AFQX | CONTACT POSITION ARRANGEMENT STYLE | 14S-5 SINGLE MATING END |
AFQW | MATING END QUANTITY | 1 |
AFRC | CONTACT MAXIMUM CURRENT RATING IN AMPS | 22.0 SINGLE MATING END SINGLE CONTACT GROUPING |
AAJD | THREAD CLASS | 2A AND 2B |
CXCL | INCLUDED CONTACT TYPE | ROUND SOCKET SINGLE MATING END SINGLE CONTACT GROUPING |
ZZZK | SPECIFICATION/STANDARD DATA | 81349-MILC5015 GOVERNMENT SPECIFICATION |
AFRP | INSERT POSITION IN DEG | 0.0 |
AFRE | CONTACT MAXIMUM DC VOLTAGE RATING IN VOLTS | 250.0 SINGLE MATING END SINGLE CONTACT GROUPING |
AFRT | SHELL TYPE | SOLID |
AFRV | CONNECTOR LOCKING METHOD | INTERNALLY THREADED COUPLING RING |
AFRN | POLARIZATION METHOD | KEYWAY OR MULTIPLE KEYWAY |
AAJF | THREAD DIRECTION | RIGHT-HAND AND RIGHT-HAND |
AFQR | THREADED DEVICE TYPE | BACK SHELL AND COUPLING FACILITY |
ADMW | BODY ANGLE IN DEG | 90.0 |
CSCF | TERMINAL TYPE | SOLDER WELL SINGLE MATING END SINGLE CONTACT GROUPING |
AKFA | DISTANCE FROM CENTERLINE TO CABLE END | 1.781 INCHES MAXIMUM |
AKEZ | DISTANCE FROM CENTERLINE TO CONNECTOR END | 2.125 INCHES MAXIMUM |
CQTM | TERMINAL LOCATION | BACK SINGLE MATING END SINGLE CONTACT GROUPING |
ADAV | OVERALL DIAMETER | 1.156 INCHES MAXIMUM |
CSPT | SHELL MATERIAL | ALUMINUM ALLOY |
CQJX | NOMINAL THREAD SIZE | 0.750 INCHES AND 0.875 INCHES |
AFQZ | CONTACT REMOVABILITY | NONREMOVABLE SINGLE MATING END SINGLE CONTACT GROUPING |
CXCG | INCLUDED CONTACT QUANTITY | 5 SINGLE MATING END SINGLE CONTACT GROUPING |
AAQL | BODY STYLE | ANGLE SHAPE, W/O CABLE CLAMP |
THSD | THREAD SERIES DESIGNATOR | UNEF AND UNEF |
TEST | TEST DATA DOCUMENT | 81349-MILC5015 SPECIFICATION |
AFRD | CONTACT MAXIMUM AC VOLTAGE RATING IN VOLTS | 200.0 SINGLE MATING END SINGLE CONTACT GROUPING |