Part Number
Part Number:
NSN:
NIIN:
Item Name:
RELAY , ELECTROMAGNETIC
Definition:
A RELAY WHICH IS ACTUATED BY THE EFFECT OF A MAGNETIC FIELD DEVELOPED BY THE CURRENT IN ITS ENERGIZING COIL(S). INCLUDES SOLENOID AND ARMATURE TYPES. EXCLUDES CONTACTOR, MAGNETIC; RELAY, METER MOVEMENT; RELAY, MOTOR DRIVEN; RELAY, REED; RELAY, RESONANT REED; RELAY, ROTARY; AND SWITCH, STEPPING.
CAGE Information
Code | Company |
---|---|
63743 | WARD LEONARD ELECTRIC COMPANY INC. |
Federal Supply Class
Title
RELAYS AND SOLENOIDS
Inclusions:
INCLUDES ELECTROMAGNETIC ACTUATORS.
Exclusions:
EXCLUDES CONTRACTORS.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AKDX | WINDING QUANTITY | 1 |
ABHP | OVERALL LENGTH | 3.125 INCHES MAXIMUM |
BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.099 INCHES NOMINAL SINGLE MOUNTING FACILITY |
CRXH | TIME DELAY | 0.05 SECONDS MAXIMUM FIXED OPERATE AND RELEASE TIME |
ADZC | ENVIRONMENTAL PROTECTION | DUSTPROOF |
AFJN | FRAGILITY FACTOR | MODERATELY RUGGED |
AJSS | FREQUENCY IN HERTZ | 60.0 NOMINAL |
CRNG | NONPILE-UP MAIN CONTACT ARRANGEMENT | 4 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
APCN | COIL QUANTITY | 1 |
CWAB | MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 20.0 AC |
ABMK | OVERALL WIDTH | 2.000 INCHES MAXIMUM |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 1 UNTHREADED HOLE SINGLE MOUNTING FACILITY |
ABKW | OVERALL HEIGHT | 1.436 INCHES MAXIMUM |
CBME | CUBIC MEASURE | 8.975 CUBIC INCHES |
APNQ | ARC QUENCHING METHOD | AIR |
AKSL | PURPOSE FOR WHICH DESIGNED | GENERAL |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 100.0 MILLIAMPERES AC RESISTIVE LOAD |
APNP | DUTY TYPE | CONTINUOUS |
CSXF | OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 120.0 VOLTS -80 DEG FAHRENHEIT TYPE 4F SINGLE WINDING |
ADTV | CASE MATERIAL | METAL |
TTQY | TERMINAL TYPE AND QUANTITY | 14 SCREW ALL FUNCTIONS |