VALVE , EXPANSION

Definition:

A SELF-ACTING VALVE SPECIFICALLY DESIGNED FOR USE IN REFRIGERATION SYSTEMS FOR CONTINUAL CONTROL OF RATE OF FLOW OF REFRIGERANT. IT MAY BE ACTUATED BY A THERMOSTATIC ELEMENT OR SELF-ACTUATED.

CAGE Information

Code Company
10855 CARRIER CORPORATION DIV CARRIER TRAN

Federal Supply Class

Title

VALVES, NONPOWERED

Inclusions:

INCLUDES AUTOMATIC NONPOWERED VALVES; GATE, GLOBE, ANGLE, CHECK, AND RELIEF VALVES; COCKS.

Exclusions:

EXCLUDES FIRE HYDRANTS (FSC 4210); SPRINKLER HEADS (FSC 4210); VALVES SPECIFICALLY DESIGNED FOR USE WITH FIRE FIGHTING EQUIPMENT (FSC 4210); PLUMBING EQUIPMENT, AND THE LIKE (FSC 4540).

Characteristics (Decoded)

MRC Requirements Statement Clear Text Reply
ACLH FIRST END OUTSIDE DIAMETER TUBE ACCOMMODATED 0.375 INCHES NOMINAL
ACLH FIRST END OUTSIDE DIAMETER TUBE ACCOMMODATED 0.375 INCHES NOMINAL
ADSW ADJUSTABLE PRESSURE RANGE +0.1/+35.0 POUNDS PER SQUARE INCH
AFKU VALVE EQUALIZER LOCATION INTERNAL
ACKL MEDIA FOR WHICH DESIGNED SULPHUR DIOXIDE, GASEOUS
ACMS SECOND END THREAD DIRECTION RIGHT-HAND
ACLL FIRST END THREAD DIRECTION RIGHT-HAND
AAQL BODY STYLE STRAIGHT THRU
AFKM VALVE PRESSURE LIMITING DEVICE NOT INCLUDED
ACKL MEDIA FOR WHICH DESIGNED METHYL CHLORIDE, GAS
ACMN SECOND END NOMINAL PIPE SIZE ACCOMMODATED 0.250 INCHES
ACLJ FIRST END THREAD SIZE AND SERIES/TYPE DESIGNATOR 0.625-18 UNF
ADQZ END CONNECTION QUANTITY 2
ACTE FIRST END SEAT ANGLE IN DEG 45.0
ACKL MEDIA FOR WHICH DESIGNED REFRIGERANT 12
ACLR SECOND END RELATIONSHIP WITH FIRST END NOT IDENTICAL
ADQU FLOW CONTROL DEVICE ANY ACCEPTABLE
ACLT SECOND END STYLE DESIGNATOR PLAIN
ABJH TEMP RATING NOT RATED
ACLK FIRST END THREAD CLASS 2A
ACMQ SECOND END THREAD SIZE AND SERIES/TYPE DESIGNATOR 0.250-18 NPT
ACKM FIRST END CONNECTION TYPE THREADED EXTERNAL TUBE
ACLS SECOND END CONNECTION TYPE THREADED INTERNAL PIPE
AFKK VALVE EXPANSION CONTROL TYPE PRESSURE
AAFZ BODY MATERIAL BRASS
ACKN FIRST END STYLE DESIGNATOR FLARED
AAJP OUTSIDE SURFACE TREATMENT ANY ACCEPTABLE
AGUB REFRIGERATION CAPACITY IN BTU PER HOUR 25.2