Part Number
Part Number:
NSN:
NIIN:
Item Name:
HOSE , NONMETALLIC
Definition:
A FLEXIBLE, TUBULAR ITEM HAVING A NONMETALLIC TUBE INNER CONVEYING SURFACE AND ONE OR MORE REINFORCEMENT LAYERS OF A METALLIC OR NONMETALLIC MATERIAL. IT IS DESIGNED TO CONVEY GASSES, LIQUIDS, OR SOLIDS. FOR ITEMS WITH FITTINGS ON ONE OR BOTH ENDS, SEE HOSE ASSEMBLY, NONMETALLIC. EXCLUDES HOSE, AIR DUCT; AND HOSE AIR DUCT, AIR BREATHING.
CAGE Information
Code | Company |
---|---|
13174 | PARKER HANNIFIN CORP HOSE PRODUCTS D |
Federal Supply Class
Title
HOSE AND FLEXIBLE TUBING
Inclusions:
INCLUDES AIR DUCT, METALLIC, NONMETALLIC, AND TEXTILE FIBER HOSES AND THEIR ASSEMBLIES; FLEXIBLE TUBING AND THEIR ASSEMBLIES.
Exclusions:
EXCLUDES CONDUIT AND THEIR ASSEMBLIES (FSC 5975); LABORATORY TUBES (FSC 6640); MEDICAL AND SURGICAL TUBES (FSC 6515); RIGID TUBING AND THEIR ASSEMBLIES (FSC 4710).
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
CRWL | INSIDE SURFACE CONDITION | SMOOTH |
AAGR | CROSS-SECTIONAL SHAPE STYLE | ROUND |
CQGM | MAXIMUM OPERATING PRESSURE | 6000.0 POUNDS PER SQUARE INCH SINGLE RESPONSE |
ABJH | TEMP RATING | -40.0 DEG FAHRENHEIT SINGLE RESPONSE AND 250.0 DEG FAHRENHEIT SINGLE RESPONSE |
FEAT | SPECIAL FEATURES | U/O 60K LOADER |
CQCS | LAYER COMPOSITION AND LOCATION | 5TH LAYER SPIRALLY LAID STEEL WIRE ERR-100 |
MATT | MATERIAL | RUBBER SYNTHETIC TUBE |
CQCS | LAYER COMPOSITION AND LOCATION | 2ND LAYER SPIRALLY LAID STEEL WIRE ERR-100 |
CQBD | BURST TEST PRESSURE | 24000.0 POUNDS PER SQUARE INCH SINGLE RESPONSE |
CQCS | LAYER COMPOSITION AND LOCATION | 6TH LAYER SPIRALLY LAID STEEL WIRE ERR-100 |
CQCS | LAYER COMPOSITION AND LOCATION | OUTER LAYER MOLDED RUBBER, SYNTHETIC ERR-100 |
CQCS | LAYER COMPOSITION AND LOCATION | 3RD LAYER SPIRALLY LAID STEEL WIRE ERR-100 |
CRDW | HYDROSTATIC TEST PRESSURE | 12000.0 POUNDS PER SQUARE INCH SINGLE RESPONSE |
CQCS | LAYER COMPOSITION AND LOCATION | 4TH LAYER SPIRALLY LAID STEEL WIRE ERR-100 |
MEDA | MEDIA FOR WHICH DESIGNED | FUEL/OIL, HYDROCARBON SINGLE RESPONSE |
CQCS | LAYER COMPOSITION AND LOCATION | 1ST LAYER SPIRALLY LAID STEEL WIRE ERR-100 |
ACKH | MINIMUM INSIDE BENDING RADIUS | 12.000 INCHES |
ABKV | OUTSIDE DIAMETER | 1.650 INCHES NOMINAL |
AARX | INSIDE DIAMETER | 1.000 INCHES NOMINAL |