Part Number
Part Number:
NSN:
NIIN:
Item Name:
PUMP UNIT , CENTRIFUGAL
Definition:
AN ASSEMBLED UNIT CONSISTING OF A COMMONLY MOUNTED CENTRIFUGAL PUMP(S), PRIME MOVER(S), AND THE NECESSARY COMPONENTS TO PROVIDE FOR A COMPLETE OPERATION.
CAGE Information
Code | Company |
---|---|
83130 | BUFFALO PUMPS INC. |
Federal Supply Class
Title
POWER AND HAND PUMPS
Inclusions:
Exclusions:
EXCLUDES LABORATORY JET PUMPS (FSG 65 AND 66).
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
FREQ | FREQUENCY IN HERTZ | 60.0 |
AHZF | CENTRIFUGAL PUMP IMPELLER QUANTITY | 1 |
AHZV | SUBMERSIBILITY (NON-CORE) | NONSUBMERSIBLE |
ADZC | ENVIRONMENTAL PROTECTION | DRIPPROOF |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
ACKL | MEDIA FOR WHICH DESIGNED | WATER, SALT |
AHYV | MAXIMUM DISCHARGE FLOW RATE | 160.0 GALLONS PER MINUTE |
AAXS | PRIME MOVER COOLING MEDIUM | AIR |
CBBL | FEATURES PROVIDED | SELF-PRIMING |
AENC | PUMP QUANTITY | 1 |
AKDJ | PRIME MOVER TYPE | ELECTRIC MOTOR |
AHZG | CENTRIFUGAL PUMP IMPELLER SUCTION TYPE | SINGLE |
CSYL | PRIME MOVER POWER RATING | 15.000 HORSEPOWER |
FAAZ | PHASE | THREE |
AHZA | PUMPING ELEMENT OPERATING POSITION | HORIZONTAL |
AAYU | INTAKE CONNECTION TYPE | ROUND FLANGE |
AAYT | INTAKE CONNECTION QUANTITY | 1 |
AENK | COOLING METHOD | AIR TO AIR COOLED |
AAXH | PRIME MOVER QUANTITY | 1 |
AAYW | DISCHARGE CONNECTION TYPE | ROUND FLANGE |
AAYD | STAGE QUANTITY | 1 |
AMPS | CURRENT RATING IN AMPS | 19.0 |
AAYV | DISCHARGE CONNECTION QUANTITY | 1 |
AAXX | MOUNTING TYPE | BASE |
ACDC | CURRENT TYPE | AC |
ZZZT | NONDEFINITIVE SPEC/STD DATA | 7N TYPE |
AHZE | CENTRIFUGAL PUMP DESIGN | MIXED FLOW |
AHYZ | OPERATING SPEED AT RATED CAPACITY | 3500.0 REVOLUTIONS PER MINUTE |
AHYX | TOTAL HEAD | 66.500 FEET |
ELEC | VOLTAGE IN VOLTS | 440.0 |