Part Number
Part Number:
NSN:
NIIN:
Item Name:
RELAY , ELECTROMAGNETIC
Definition:
A RELAY WHICH IS ACTUATED BY THE EFFECT OF A MAGNETIC FIELD DEVELOPED BY THE CURRENT IN ITS ENERGIZING COIL(S). INCLUDES SOLENOID AND ARMATURE TYPES. EXCLUDES CONTACTOR, MAGNETIC; RELAY, METER MOVEMENT; RELAY, MOTOR DRIVEN; RELAY, REED; RELAY, RESONANT REED; RELAY, ROTARY; AND SWITCH, STEPPING.
CAGE Information
Code | Company |
---|---|
89020 | TYCO ELECTRONICS/AGASTAT RELAYS |
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AKDX | WINDING QUANTITY | 1 |
AKDX | WINDING QUANTITY | 1 |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 2.5 AMPERES AC INDUCTIVE LOAD AND 0.5 AMPERES DC INDUCTIVE LOAD |
CWAB | MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 480.0 AC AND 220.0 DC |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 4 THREADED HOLE SINGLE MOUNTING FACILITY |
ADZC | ENVIRONMENTAL PROTECTION | DUSTPROOF |
ABHP | OVERALL LENGTH | 5.062 INCHES NOMINAL |
TTQY | TERMINAL TYPE AND QUANTITY | 6 WIRE LEAD CONTACTS |
TTQY | TERMINAL TYPE AND QUANTITY | 2 WIRE LEAD ENERGIZING ELEMENT |
APCN | COIL QUANTITY | 1 |
CRXH | TIME DELAY | 0.15 SECONDS MINIMUM ADJUSTABLE RELEASE TIME AND 3.00 SECONDS MAXIMUM ADJUSTABLE RELEASE TIME |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 0.250 INCHES NOMINAL SINGLE MOUNTING FACILITY |
CSXF | OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 250.0 VOLTS TEARDROP, TWO HOLES TYPE 4F SINGLE WINDING |
APNQ | ARC QUENCHING METHOD | AIR |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 0.500 INCHES NOMINAL SINGLE MOUNTING FACILITY |
CRPQ | NOMINAL OPERATING CURRENT RATING AND TYPE | 0.03 AMPERES DC SINGLE WINDING |
APNP | DUTY TYPE | CONTINUOUS |
ABMK | OVERALL WIDTH | 3.250 INCHES NOMINAL |
ABKW | OVERALL HEIGHT | 2.938 INCHES NOMINAL |
CQYJ | MOUNTING FACILITY PATTERN | RECTANGULAR SINGLE MOUNTING FACILITY |