Follow Us on Google+

Request A Price Quote:

National Stock Number (NSN) Output Data

NSN:
NIIN:
Item Name:
TRANSFORMER , POWER

Definition:

A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.

Reference/Part Number

Part Number CAGE Status RNCC RNVC DAC RNAAC MSDS SADC
244-001-015 86301 A 5 2 5 ZZ
MIL-T-15108 81349 M 4 1 E TX
S6202-3223863GP3 80064 A 3 2 A TX
5324 75138 F 5 9 5 TX
5324G3 75138 F 5 9 5 TX
5324G3 86301 A 5 1 5 ZZ

CAGE Information

Code Company
75138 SHERJOR INC
86301 POWER PARAGON INC DBA POWER MAGNETIC
81349 MILITARY SPECIFICATIONS PROMULGATED
80064 NAVAL SHIP SYSTEMS COMMAND

Federal Supply Class

Title

COILS AND TRANSFORMERS

Inclusions:

INCLUDES COILS, EXCEPT IGNITION AND MAGNETO; COIL ASSEMBLIES; REACTORS; TRANSFORMERS.

Exclusions:

Characteristics (Decoded)

MRC Requirements Statement Clear Text Reply
AKPV MOUNTING FACILITY QUANTITY 4 SINGLE GROUP
ADAU BODY HEIGHT 9.156 INCHES NOMINAL
AKNA INCLOSURE TYPE FULLY INCLOSED
ADAQ BODY LENGTH 11.188 INCHES NOMINAL
BFMF COOLING METHOD SELF-COOLED
TTQY TERMINAL TYPE AND QUANTITY 4 WIRE LEAD
AEJN DISTANCE BETWEEN MOUNTING FACILITY CENTERS 7.250 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
CWJS WINDING OPERATING VOLTAGE 120.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE SECONDARY
ACZX WINDING SHIELDING METHOD EXTERNAL INCLOSURE SINGLE COMPONENT
ACZF MAXIMUM TRANSFORMER POWER RATING 3.0 KILOVOLT-AMPERE SINGLE COMPONENT
BPLC WINDING FUNCTION AND QUANTITY 1 PRIMARY SINGLE COMPONENT AND 1 SECONDARY SINGLE COMPONENT
ADAT BODY WIDTH 9.531 INCHES NOMINAL
AXGY MOUNTING METHOD UNTHREADED HOLE SINGLE GROUP
AYTS COOLING TYPE FINS
ACZC INPUT-OUTPUT PHASE RELATIONSHIP SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
ABTB MOUNTING HOLE DIAMETER 0.438 INCHES NOMINAL SINGLE GROUP
CWJS WINDING OPERATING VOLTAGE 450.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY
ACZB FREQUENCY RATING 60.0 HERTZ NOMINAL SINGLE COMPONENT

Similar Parts

5324 , 5324 , 5950-00-548-0481 , 5950005480481 , 005480481 , 244-001-015 , MIL-T-15108 , S6202-3223863GP3 , 5324 , 5324G3 , 5324G3 ,