Part Number
Definition:
A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.
CAGE Information
Code | Company |
---|---|
86632 | NEWTON ENGINEERING SERVICE INC |
Federal Supply Class
Title
COILS AND TRANSFORMERS
Inclusions:
INCLUDES COILS, EXCEPT IGNITION AND MAGNETO; COIL ASSEMBLIES; REACTORS; TRANSFORMERS.
Exclusions:
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
ABTB | MOUNTING HOLE DIAMETER | 0.176 INCHES MINIMUM SINGLE GROUP AND 0.182 INCHES MAXIMUM SINGLE GROUP |
ACZF | MAXIMUM TRANSFORMER POWER RATING | 98.8 VOLT-AMPERE SINGLE COMPONENT |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
CRMJ | WINDING POWER RATING | 57.2 VOLTS-AMPERES SINGLE COMPONENT 2ND SECONDARY |
ADAQ | BODY LENGTH | 4.470 INCHES MINIMUM AND 5.530 INCHES MAXIMUM |
ADAT | BODY WIDTH | 2.750 INCHES MAXIMUM |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
CRBZ | WINDING OPERATING CURRENT | 1.1 AMPERES MAXIMUM OF STANDARD RANGE B SINGLE COMPONENT 2ND SECONDARY |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 6.240 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 6.260 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 2 SECONDARY SINGLE COMPONENT |
AXGY | MOUNTING METHOD | UNTHREADED HOLE SINGLE GROUP |
AEHZ | MAXIMUM OPERATING TEMP | 95.0 DEG CELSIUS |
CWJS | WINDING OPERATING VOLTAGE | 115.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
ABHP | OVERALL LENGTH | 6.750 INCHES MAXIMUM |
ADAU | BODY HEIGHT | 3.000 INCHES MAXIMUM |
CRMJ | WINDING POWER RATING | 41.6 VOLTS-AMPERES SINGLE COMPONENT 1ST SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 32.00 AC POUNDS PER HOUR WET SINGLE COMPONENT 1ST SECONDARY |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 1.990 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 2.010 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ACZB | FREQUENCY RATING | 55.0 HERTZ MINIMUM SINGLE COMPONENT AND 65.0 HERTZ MAXIMUM SINGLE COMPONENT |
TTQY | TERMINAL TYPE AND QUANTITY | 6 WIRE HOOK |
CRBZ | WINDING OPERATING CURRENT | 1.3 AMPERES MAXIMUM OF STANDARD RANGE B SINGLE COMPONENT 1ST SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 52.00 AC POUNDS PER HOUR WET SINGLE COMPONENT 2ND SECONDARY |