A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.
CAGE Information
Code | Company |
---|---|
86632 | NEWTON ENGINEERING SERVICE INC |
Federal Supply Class
Title
COILS AND TRANSFORMERS
Inclusions:
INCLUDES COILS, EXCEPT IGNITION AND MAGNETO; COIL ASSEMBLIES; REACTORS; TRANSFORMERS.
Exclusions:
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
ACZB | FREQUENCY RATING | 50.0 HERTZ MINIMUM SINGLE COMPONENT AND 400.0 HERTZ MAXIMUM SINGLE COMPONENT |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
CRBZ | WINDING OPERATING CURRENT | 20.0 MILLIAMPERES NOMINAL B SINGLE COMPONENT 4TH SECONDARY |
AAJD | THREAD CLASS (NON-CORE) | 2B SINGLE GROUP |
FEAT | SPECIAL FEATURES | 2 PRIMARIES AND 5 SECONDARIES |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
TTQY | TERMINAL TYPE AND QUANTITY | 15 THREADED STUD |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 5.750 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
THSD | THREAD SERIES DESIGNATOR | UNC SINGLE GROUP |
CWJS | WINDING OPERATING VOLTAGE | 115.80 AC POUNDS PER HOUR WET SINGLE COMPONENT 1ST SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 1.4 AMPERES NOMINAL B SINGLE COMPONENT 1ST SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 3.0 AMPERES NOMINAL B SINGLE COMPONENT 2ND SECONDARY |
AAJF | THREAD DIRECTION (NON-CORE) | RIGHT-HAND SINGLE GROUP |
CWJS | WINDING OPERATING VOLTAGE | 11.50 AC POUNDS PER HOUR WET SINGLE COMPONENT 2ND SECONDARY |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
AXGY | MOUNTING METHOD | THREADED HOLE SINGLE GROUP |
ADAT | BODY WIDTH | 5.880 INCHES NOMINAL |
ADAQ | BODY LENGTH | 7.000 INCHES NOMINAL |
CRBZ | WINDING OPERATING CURRENT | 1.5 AMPERES NOMINAL B SINGLE COMPONENT 3RD SECONDARY |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 5.000 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
CWJS | WINDING OPERATING VOLTAGE | 85.00 AC POUNDS PER HOUR WET SINGLE COMPONENT 4TH SECONDARY |
BPLC | WINDING FUNCTION AND QUANTITY | 2 PRIMARY SINGLE COMPONENT AND 5 SECONDARY SINGLE COMPONENT |
ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD GROUNDED TO CORE SINGLE COMPONENT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
CWJS | WINDING OPERATING VOLTAGE | 115.00 AC POUNDS PER HOUR WET SINGLE COMPONENT ALL PRIMARY OR 230.00 AC POUNDS PER HOUR WET SINGLE COMPONENT ALL PRIMARY |
CQJX | NOMINAL THREAD SIZE | 0.250 INCHES SINGLE GROUP |
ADAU | BODY HEIGHT | 5.880 INCHES NOMINAL |
CWJS | WINDING OPERATING VOLTAGE | 13.60 AC POUNDS PER HOUR WET SINGLE COMPONENT 3RD SECONDARY |