Part Number
Definition:
A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.
CAGE Information
Code | Company |
---|---|
86632 | NEWTON ENGINEERING SERVICE INC |
Federal Supply Class
Title
COILS AND TRANSFORMERS
Inclusions:
INCLUDES COILS, EXCEPT IGNITION AND MAGNETO; COIL ASSEMBLIES; REACTORS; TRANSFORMERS.
Exclusions:
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AXGY | MOUNTING METHOD | THREADED HOLE 2ND GROUP |
AAJD | THREAD CLASS (NON-CORE) | 2B 2ND GROUP |
CWJS | WINDING OPERATING VOLTAGE | 115.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE SECONDARY |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.500 INCHES NOMINAL 2ND MOUNTING FACILITY SINGLE CENTER GROUP |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 1.980 INCHES MINIMUM 2ND MOUNTING FACILITY SINGLE CENTER GROUP AND 2.020 INCHES MAXIMUM 2ND MOUNTING FACILITY SINGLE CENTER GROUP |
ADAT | BODY WIDTH | 2.690 INCHES MINIMUM AND 2.750 INCHES MAXIMUM |
ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD GROUNDED TO INCLOSURE AND CORE SINGLE COMPONENT |
CRBZ | WINDING OPERATING CURRENT | 1.1 AMPERES NOMINAL B SINGLE COMPONENT SINGLE SECONDARY |
AAJF | THREAD DIRECTION (NON-CORE) | RIGHT-HAND 2ND GROUP |
CQJX | NOMINAL THREAD SIZE | 0.138 INCHES 2ND GROUP |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
AEJN | DISTANCE BETWEEN MOUNTING FACILITY CENTERS | 1.980 INCHES MINIMUM 1ST MOUNTING FACILITY SINGLE CENTER GROUP AND 2.020 INCHES MAXIMUM 1ST MOUNTING FACILITY SINGLE CENTER GROUP |
ACZF | MAXIMUM TRANSFORMER POWER RATING | 126.5 VOLT-AMPERE SINGLE COMPONENT |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 1 SECONDARY SINGLE COMPONENT |
AKPV | MOUNTING FACILITY QUANTITY | 2 1ST GROUP |
ADAQ | BODY LENGTH | 8.060 INCHES MINIMUM AND 8.120 INCHES MAXIMUM |
AEHZ | MAXIMUM OPERATING TEMP | 95.0 DEG CELSIUS |
CWJS | WINDING OPERATING VOLTAGE | 115.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
AKPV | MOUNTING FACILITY QUANTITY | 4 2ND GROUP |
AXGY | MOUNTING METHOD | SLOT 1ST GROUP |
ADAU | BODY HEIGHT | 3.000 INCHES MAXIMUM |
ABTD | MOUNTING SLOT WIDTH | 0.183 INCHES MINIMUM 1ST GROUP AND 0.193 INCHES MAXIMUM 1ST GROUP |
TTQY | TERMINAL TYPE AND QUANTITY | 3 CONNECTOR, RECEPTACLE |
ACZB | FREQUENCY RATING | 55.0 HERTZ MINIMUM SINGLE COMPONENT AND 65.0 HERTZ MAXIMUM SINGLE COMPONENT |
THSD | THREAD SERIES DESIGNATOR | UNC 2ND GROUP |