Part Number
Part Number:
NSN:
NIIN:
Item Name:
PUMP UNIT , ROTARY
Definition:
AN ASSEMBLED UNIT CONSISTING OF A COMMONLY MOUNTED ROTARY PUMP(S), PRIME MOVER(S), AND THE NECESSARY COMPONENTS TO PROVIDE FOR A COMPLETE OPERATION.
CAGE Information
Code | Company |
---|---|
24902 | GILBARCO INC. DBA GILBARCO VEEDER-RO |
Federal Supply Class
Title
POWER AND HAND PUMPS
Inclusions:
Exclusions:
EXCLUDES LABORATORY JET PUMPS (FSG 65 AND 66).
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
FREQ | FREQUENCY IN HERTZ | 60.0 |
ZZZY | REFERENCE NUMBER DIFFERENTIATING CHARACTERISTICS | AS DIFFERENTIATED BY HOUSING NOT IN ACCORDANCE W/NEMA STD ANDMOTOR WESTINGHOUSE ELECTRIC CORP DWG NO. 904J523 |
AENK | COOLING METHOD | SELF VENTILATED |
AMPS | CURRENT RATING IN AMPS | 52.0 |
ADZC | ENVIRONMENTAL PROTECTION | SPLASH PROOF |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
AAXS | PRIME MOVER COOLING MEDIUM | AIR |
AENC | PUMP QUANTITY | 1 |
AHYW | DISCHARGE PRESSURE | 50.0 POUNDS PER SQUARE INCH GAGE |
AKDJ | PRIME MOVER TYPE | ELECTRIC MOTOR |
FAAZ | PHASE | THREE |
ZZZT | NONDEFINITIVE SPEC/STD DATA | 2SSJCL0-1 TYPE |
AHYZ | OPERATING SPEED AT RATED CAPACITY | 1150.0 REVOLUTIONS PER MINUTE |
CSYL | PRIME MOVER POWER RATING | 40.000 HORSEPOWER |
AHZR | ROTARY PUMP DESIGN | SCREW |
ACKL | MEDIA FOR WHICH DESIGNED | OIL |
AAYU | INTAKE CONNECTION TYPE | ROUND FLANGE |
AHZA | PUMPING ELEMENT OPERATING POSITION | VERTICAL |
AAYT | INTAKE CONNECTION QUANTITY | 1 |
AAXH | PRIME MOVER QUANTITY | 1 |
AAYW | DISCHARGE CONNECTION TYPE | ROUND FLANGE |
AAYV | DISCHARGE CONNECTION QUANTITY | 1 |
AHYV | MAXIMUM DISCHARGE FLOW RATE | 400.0 GALLONS PER MINUTE |
ACDC | CURRENT TYPE | AC |
ELEC | VOLTAGE IN VOLTS | 440.0 |