Part Number
Part Number:
NSN:
NIIN:
Item Name:
RELAY , ELECTROMAGNETIC
Definition:
A RELAY WHICH IS ACTUATED BY THE EFFECT OF A MAGNETIC FIELD DEVELOPED BY THE CURRENT IN ITS ENERGIZING COIL(S). INCLUDES SOLENOID AND ARMATURE TYPES. EXCLUDES CONTACTOR, MAGNETIC; RELAY, METER MOVEMENT; RELAY, MOTOR DRIVEN; RELAY, REED; RELAY, RESONANT REED; RELAY, ROTARY; AND SWITCH, STEPPING.
CAGE Information
Code | Company |
---|---|
56232 | LOCKHEED MARTIN CORPORATION DBA LOCK |
Federal Supply Class
Title
RELAYS AND SOLENOIDS
Inclusions:
INCLUDES ELECTROMAGNETIC ACTUATORS.
Exclusions:
EXCLUDES CONTRACTORS.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
CSXF | OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 50.0 VOLTS TEARDROP, TWO HOLES TYPE 4F SINGLE WINDING |
AKDX | WINDING QUANTITY | 1 |
ABKW | OVERALL HEIGHT | 0.875 INCHES NOMINAL |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 1.062 INCHES NOMINAL SINGLE MOUNTING FACILITY |
ABMK | OVERALL WIDTH | 0.406 INCHES NOMINAL |
APCN | COIL QUANTITY | 1 |
AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.120 INCHES NOMINAL SINGLE MOUNTING FACILITY |
APNA | WINDING DC RESISTANCE RATING | 2.53 KILOHMS NOMINAL SINGLE WINDING |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 2 UNTHREADED HOLE SINGLE MOUNTING FACILITY |
ABHP | OVERALL LENGTH | 1.330 INCHES NOMINAL |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 2.0 AMPERES AC RESISTIVE LOAD AND 600.0 MILLIAMPERES DC RESISTIVE LOAD |
ADZC | ENVIRONMENTAL PROTECTION | HERMETIC |
TTQY | TERMINAL TYPE AND QUANTITY | 8 PIN ALL FUNCTIONS |
APNP | DUTY TYPE | CONTINUOUS |
AYSC | PILE-UP MAIN CONTACT FORM ARRANGEMENT | 2C |
CQYJ | MOUNTING FACILITY PATTERN | IN-LINE SINGLE MOUNTING FACILITY |
CWAB | MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 115.0 AC AND 50.0 DC |