Part Number
Definition:
A RIGID OR FLEXIBLE TUBING HAVING UNIFORM INSIDE AND OUTSIDE DIAMETERS IN THE OVERALL LENGTH. IT IS SPECIFICALLY DESIGNED TO PREVENT ANY UNDESIRABLE FLOW OF CURRENT BETWEEN CONDUCTORS AND OTHER OBJECTS. INCLUDES SHRINKABLE TYPE TUBING, ITEMS IN BULK AND IN SPECIFIC FABRICATED LENGTHS (CUT TO SIZE). EXCLUDES ITEMS NOT HAVING RATED ELECTRICAL CHARACTERISTICS. ALSO EXCLUDES BUSHING, SLEEVE; CABLE NIPPLE, ELECTRICAL; CONDUIT (AS MODIFIED); INSULATION SLEEVING, ELECTRICAL, SPECIAL PURPOSE; INSULATION SLEEVING, THERMAL; SLEEVE, MARKER, CABLE; SLEEVING, TEXTILE, ELECTRICAL; TUBING, GLASS; AND TUBING, NONMETALLIC.
CAGE Information
Code | Company |
---|---|
81755 | LOCKHEED MARTIN CORPORATION DBA LOCK |
Federal Supply Class
Title
ELECTRICAL INSULATORS AND INSULA
Inclusions:
INCLUDES TUBE, KNOB, CLEAT, STRAIN, AND STANDOFF INSULATORS; FEED THRU INSULATORS; BEAD INSULATORS; VARNISH CAMBRIC TAPE; FRICTION TAPE.
Exclusions:
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
CQBC | MINIMUM TENSILE STRENGTH | 3000 POUNDS PER SQUARE INCH |
FLEX | FLEXIBILITY | FLEXIBLE |
ABHP | OVERALL LENGTH | ANY ACCEPTABLE |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ZZZK | SPECIFICATION/STANDARD DATA | 81346-ASTMD3295 PROFESSIONAL/INDUSTRIAL ASSOCIATION STANDARD |
ZZZT | NONDEFINITIVE SPEC/STD DATA | C CLASS AND 10AWG SIZE AND 1 TYPE |
ABJH | TEMP RATING | 327.0 DEG CELSIUS |
AAGT | WALL THICKNESS | 0.016 INCHES NOMINAL |
STYL | STYLE DESIGNATOR | NONSHRINKABLE |
AAPB | DIELECTRIC WITHSTANDING VOLTAGE IN VOLTS | 16300.0 |
HUES | COLOR | WHITE |
ZZZX | DEPARTURE FROM CITED DESIGNATOR | AS MODIFIED BY COLOR |
ADZC | ENVIRONMENTAL PROTECTION | ANY ACCEPTABLE |
AARX | INSIDE DIAMETER | 0.102 INCHES MINIMUM AND 0.112 INCHES MAXIMUM |
MATL | MATERIAL | PLASTIC, POLYTETRAFLUOROETHYLENE RESIN |