Follow Us on Google+

Request A Price Quote:

Part Number

Part Number:
NSN:
NIIN:
Item Name:
SWITCH , PRESSURE

Definition:

A SWITCH WHICH IS ACTUATED BY CHANGES IN PRESSURE OF ANY GAS OR LIQUID OR BY CHANGES IN A VACUUM ACTING UPON ITS SENSING ELEMENT. EXCLUDES BAROSWITCH; SWITCH, PRESSURE-THERMOSTATIC; AND SWITCH, SENSITIVE.

CAGE Information

Code Company
14314 UNITED ELECTRIC CONTROLS COMPANY DBA

Federal Supply Class

Title

SWITCHES

Inclusions:

INCLUDES ROTARY, KNIFE, TOGGLE, PUSH BUTTON, MERCURY, THERMOSTATIC, AND DIFFERENTIAL PRESSURE SWITCHES.

Exclusions:

EXCLUDES SWITCHGEAR.

Characteristics (Decoded)

MRC Requirements Statement Clear Text Reply
CTZL PRESSURE CONNECTOR TYPE FLARED, THREADED EXTERNAL SINGLE CONNECTION
CTZL PRESSURE CONNECTOR TYPE FLARED, THREADED EXTERNAL SINGLE CONNECTION
CQJB PROOF PRESSURE 35.00 POUNDS PER SQUARE INCH
AWTN OPERATING TEMP RATING -65.0 DEG FAHRENHEIT MINIMUM AND 160.0 DEG FAHRENHEIT MAXIMUM
CQJX NOMINAL THREAD SIZE 0.4375 INCHES SINGLE PRESSURE CONNECTION
AASA THREAD LENGTH 0.188 INCHES NOMINAL SINGLE PRESSURE CONNECTION
CTYC CONTACT ADJUSTABILITY DEACTUATION POINT NOT ADJUSTABLE AND ACTUATION POINT NOT ADJUSTABLE
ADAV OVERALL DIAMETER 2.500 INCHES NOMINAL
CMLP THREAD QUANTITY PER INCH 20 SINGLE PRESSURE CONNECTION
CTZB CONTACT VOLTAGE RATING IN VOLTS 28.0 DC AT SEA LEVEL SINGLE VOLTAGE
CTYX CONTACT STIMULUS RATING 15.00 DEACTUATION POINT NOMINAL INCHES OF WATER AND 5.00 DIFFERENTIAL POINT NOMINAL INCHES OF WATER
AXGY MOUNTING METHOD CLAMP
CQGB CONTACT ACTION STIMULUS INCREASE
MEDA MEDIA FOR WHICH DESIGNED GAS OR LIQUID
AAJD THREAD CLASS 3A SINGLE PRESSURE CONNECTION
CSCC SENSING ELEMENT BURST PRESSURE 70.00 POUNDS PER SQUARE INCH
CTHF CONTACT LOAD CURRENT RATING 5.0 AMPERES RESISTIVE LOAD FIRST VOLTAGE
STYL STYLE DESIGNATOR CYLINDRICAL
ASDB WIDTH ACROSS FLATS 0.688 INCHES NOMINAL
ABHP OVERALL LENGTH 3.550 INCHES NOMINAL
CRLD NONPILE-UP CONTACT ARRANGEMENT 1 POLE, DOUBLE THROW, ONE POSITION MOMENTARY
CSCF TERMINAL TYPE CONNECTOR, RECEPTACLE
ABPM BODY DIAMETER 1.750 INCHES NOMINAL
CTHF CONTACT LOAD CURRENT RATING 3.0 AMPERES INDUCTIVE LOAD SECOND VOLTAGE
THSD THREAD SERIES DESIGNATOR UNF SINGLE PRESSURE CONNECTION
AJZC PRESSURE SWITCH TYPE GAGE

Similar Parts