Part Number
Definition:
AN ITEM CONSISTING OF INSULATING MATERIAL, WHICH IS SPECIFICALLY DESIGNED TO HAVE FASTENED THEREON, OR ON WHICH ARE FASTENED TERMINAL(S), SUCH AS SCREWS, SOLDER LUGS, SOLDER STUDS, SOLDERLESS CONNECTORS, CLIPS, AND THE LIKE. IT IS USUALLY USED FOR JUNCTIONS OR TERMINATIONS OF WIRE OR CABLE ASSEMBLIES. IT DOES NOT INCLUDE ITEMS AS DEFINED ABOVE WITH PARTS, SUCH AS RESISTORS AND CAPACITORS MOUNTED THEREON. DO NOT USE IF A MORE SPECIFIC NAME EXISTS, SUCH AS FUSEHOLDER; HOLDER, RESISTOR; FANNING STRIP; CONTACT ASSEMBLY, ELECTRICAL; JACK ASSEMBLY, TIP; CHAMBER, CABLE TERMINAL; PANEL (2) (AS MODIFIED); CONNECTOR (AS MODIFIED). EXCLUDES TERMINAL, STUD; TERMINAL, FEEDTHRU, INSULATED; POST, BINDING, ELECTRICAL; AND CHASSIS, ELECTRICAL-ELECTRONIC EQUIPMENT. FOR ITEMS HAVING PRINTED ELECTRICAL CONDUCTOR PATHS, SEE PRINTED WIRING BOARD.
CAGE Information
Code | Company |
---|---|
24446 | GENERAL ELECTRIC CO |
Federal Supply Class
Title
LUGS, TERMINALS, AND TERMINAL ST
Inclusions:
INCLUDES BINDING POSTS; BATTERY CLIPS; STUD TERMINALS; TEST CLIPS.
Exclusions:
EXCLUDES CAPS, ELECTRICAL; CLIPS, ELECTRICAL; AND CONTACTS, ELECTRICAL.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AMPS | CURRENT RATING IN AMPS | 30.0 |
AMPS | CURRENT RATING IN AMPS | 30.0 |
ABGR | BOARD HEIGHT EXCLUDING TERMINALS | 1.250 INCHES |
AAMA | MOUNTING HOLE DIAMETER | 0.219 INCHES |
ABCS | TERMINAL ROW QUANTITY | 2 |
CWLG | TERMINAL PATTERN ARRANGEMENT | MULTI-ROW |
CSCR | TERMINAL CONNECTING LINK TYPE | 1 SINGLE |
ABCU | DISTANCE BETWEEN TERMINAL ROW CENTERS | 0.875 INCHES |
MDCL | MATERIAL DOCUMENT AND CLASSIFICATION | MIL-M-14,TYPE MFI-20 MIL SPEC SINGLE MATERIAL RESPONSE BOARD |
CQCZ | TERMINAL CONNECTING LINK QUANTITY | 12 SINGLE |
ABGQ | BOARD OVERALL HEIGHT | 1.891 INCHES |
ABDU | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 7.875 INCHES |
ABGS | BASE THICKNESS | 0.375 INCHES |
CWLN | TERMINAL DESIGN | NONFEEDTHRU |
CRNL | NONFEEDTHRU TERMINAL TYPE | 858 SINGLE |
CSCS | NONFEEDTHRU TERMINAL QUANTITY | 24 SINGLE |
ABDX | DISTANCE FROM LEFT EDGE OF TERMINAL BOARD TO CENTER OF FIRST MOUNTING FACILITY | 0.188 INCHES |
ABGP | BOARD OVERALL WIDTH | 2.000 INCHES |
CBBL | FEATURES PROVIDED | MARKER STRIP |
ABCX | BOARD CONSTRUCTION | HOLLOW CONSTRUCTION WITHOUT INSULATED STRIP |
ABDW | DISTANCE FROM BOTTOM EDGE OF TERMINAL BOARD TO CENTER OF MOUNTING HOLE | 1.000 INCHES |
MATT | MATERIAL | PLASTIC PHENOLIC BOARD AND ASBESTOS BOARD |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 2 UNTHREADED HOLE |
ABCT | CENTER TO CENTER DISTANCE BETWEEN TERMINALS | 0.625 INCHES |
MARK | SPECIAL MARKINGS | 1 TO 12 |
AAQL | BODY STYLE | BARRIER TYPE |
ABGN | BOARD OVERALL LENGTH | 8.250 INCHES |