Part Number
Definition:
A VALVE DESIGNED TO AUTOMATICALLY MAINTAIN WITHIN CLOSE LIMITS A PREDETERMINED OUTLET PRESSURE WHICH MAY BE ADJUSTABLE WITHIN A SPECIFIED RANGE REGARDLESS OF THE HIGHER FLUCTUATING OR CONSTANT INLET PRESSURE. IT IS DESIGNED FOR USE WITH COMPRESSED GAS(ES) AND VARIOUS LIQUIDS AND MAY INCLUDE GAUGES. IT MAY BE INLINE OR CARTRIDGE (MANIFOLD) DESIGN. EXCLUDES REGULATOR, PRESSURE, MEDICAL GAS ADMINISTRATION APPARATUS; REGULATOR, OXYGEN, BAROMETRIC CONTINUOUS FLOW; REGULATOR, OXYGEN DEMAND; REGULATOR, OXYGEN DILUTER DEMAND; AND VALVE(1), FLUID PRESSURE REGULATING, AIRCRAFT.
CAGE Information
Code | Company |
---|---|
72957 | ELLIOTT COMPANY DIV JEANNETTE |
Federal Supply Class
Title
VALVES, NONPOWERED
Inclusions:
INCLUDES AUTOMATIC NONPOWERED VALVES; GATE, GLOBE, ANGLE, CHECK, AND RELIEF VALVES; COCKS.
Exclusions:
EXCLUDES FIRE HYDRANTS (FSC 4210); SPRINKLER HEADS (FSC 4210); VALVES SPECIFICALLY DESIGNED FOR USE WITH FIRE FIGHTING EQUIPMENT (FSC 4210); PLUMBING EQUIPMENT, AND THE LIKE (FSC 4540).
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
ACKM | FIRST END CONNECTION TYPE | THREADED INTERNAL PIPE |
AEVZ | MAXIMUM INLET PRESSURE RATING | 150.0 POUNDS PER SQUARE INCH |
AAJP | OUTSIDE SURFACE TREATMENT | PAINTED |
AEVN | REGULATION TYPE | AUTOMATIC SINGLE STAGE |
ABEP | STEM MATERIAL | STEEL |
ACLL | FIRST END THREAD DIRECTION | RIGHT-HAND |
AEVR | VALVE LOADING METHOD | SPRING |
ACLJ | FIRST END THREAD SIZE AND SERIES/TYPE DESIGNATOR | 2-1/4-12 UN |
AEVA | OUTLET PRESSURE RANGE | +3.0/+30.0 POUNDS PER SQUARE INCH |
ADQZ | END CONNECTION QUANTITY | 2 |
ADQU | FLOW CONTROL DEVICE | POPPET |
ACLR | SECOND END RELATIONSHIP WITH FIRST END | IDENTICAL |
AAQL | BODY STYLE | ANGLE |
ACKN | FIRST END STYLE DESIGNATOR | PLAIN |
AEWF | FILTER | NOT INCLUDED |
AEWB | OUTLET PRESSURE ACCURACY RATING | NOT RATED |
ACKL | MEDIA FOR WHICH DESIGNED | ANY ACCEPTABLE |
AAFZ | BODY MATERIAL | BRASS |