Part Number
Definition:
A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.
CAGE Information
Code | Company |
---|---|
15634 | MAGNETIKA INC |
Federal Supply Class
Title
COILS AND TRANSFORMERS
Inclusions:
INCLUDES COILS, EXCEPT IGNITION AND MAGNETO; COIL ASSEMBLIES; REACTORS; TRANSFORMERS.
Exclusions:
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
CRBZ | WINDING OPERATING CURRENT | 600.0 MILLIAMPERES NOMINAL B AND BETTER DROP SIDING SINGLE COMPONENT SINGLE PRIMARY |
AEHZ | MAXIMUM OPERATING TEMP | 125.0 DEG CELSIUS |
CWJS | WINDING OPERATING VOLTAGE | 240.00 AC POUNDS PER HOUR WET SINGLE COMPONENT 1ST SECONDARY |
ABMK | OVERALL WIDTH | 1.380 INCHES MAXIMUM |
CWJS | WINDING OPERATING VOLTAGE | 45.10 AC POUNDS PER HOUR WET SINGLE COMPONENT 3RD SECONDARY |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 5 SECONDARY SINGLE COMPONENT |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABHP | OVERALL LENGTH | 1.500 INCHES MAXIMUM |
FEAT | SPECIAL FEATURES | 1 PRIMARY WINDING; 5 SECONDARY WINDINGS |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
TTQY | TERMINAL TYPE AND QUANTITY | 12 WIRE LEAD |
ACZB | FREQUENCY RATING | 380.0 HERTZ MINIMUM SINGLE COMPONENT AND 420.0 HERTZ MAXIMUM SINGLE COMPONENT |
AKNA | INCLOSURE TYPE | OPEN |
AXGY | MOUNTING METHOD | TERMINAL SINGLE GROUP |
ADAU | BODY HEIGHT | 1.125 INCHES NOMINAL |
CWJS | WINDING OPERATING VOLTAGE | 110.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY |
CWJS | WINDING OPERATING VOLTAGE | 46.40 AC POUNDS PER HOUR WET SINGLE COMPONENT 4TH SECONDARY |
CBBL | FEATURES PROVIDED | COLOR CODED LEAD |
CWJS | WINDING OPERATING VOLTAGE | 206.00 AC POUNDS PER HOUR WET SINGLE COMPONENT 2ND SECONDARY |