Part Number
Definition:
AN OPEN OR INCLOSED FRAME STRUCTURE DESIGNED TO ACCOMMODATE (BUT DOES NOT INCLUDE) ELECTRICAL/ELECTRONIC EQUIPMENT MOUNTED ON STANDARD WIDTH PANELS SO THAT THE EQUIPMENT MAY BE OPERATED AFTER INSTALLATION WITHOUT BEING REMOVED. IT MUST HAVE PANEL MOUNTING RAILS THAT PROVIDE A UNIFORM PATTERN OF MOUNTING HOLES THAT WILL ACCOMMODATE VARIOUS COMBINATIONS OF STANDARD WIDTH PANELS. IT MAY INCLUDE WIRES, CABLES, TERMINAL BOARDS, CONNECTORS, AND THE LIKE, REQUIRED FOR EQUIPMENT OPERATION. SEE ALSO MOUNTING BASE, ELECTRICAL EQUIPMENT; CABINET, ELECTRICAL EQUIPMENT; AND CASE (2) (AS MODIFIED). EXCLUDES MAIN DISTRIBUTING FRAME, TELEPHONE AND INTERMEDIATE DISTRIBUTING FRAME, TELEPHONE.
CAGE Information
Code | Company |
---|---|
65192 | PEPCO MANUFACTURING CO. DIV FIORE SK |
Federal Supply Class
Title
ELECTRICAL HARDWARE AND SUPPLIES
Inclusions:
INCLUDES CONDUIT; RACEWAYS; FACE PLATES; CONDULETS; OUTLET AND JUNCTION BOXES; POLE LINE HARDWARE, NOT ELSEWHERE CLASSIFIABLE.
Exclusions:
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
ABKW | OVERALL HEIGHT | 63.750 INCHES NOMINAL |
AERQ | DOOR TYPE | SINGLE FRONT |
ABDR | MOUNTING PROVISION | UNTHREADED HOLE |
AEQT | PANEL RAIL THICKNESS | 0.120 INCHES NOMINAL |
ABFY | OVERALL DEPTH | 36.000 INCHES NOMINAL |
ABMK | OVERALL WIDTH | 22.000 INCHES NOMINAL |
MATT | MATERIAL | STEEL |
CXCY | PART NAME ASSIGNED BY CONTROLLING AGENCY | SHOCK CABINET 196136 |
FEAT | SPECIAL FEATURES | INCLUDES: COMPRESSION HINGE, LIFT, LATCH; HAS 4 EMI AIR FILTERS WITH BRACKETS; ALL EXPOSED OUTSIDE SURFACES ARE PAINTED |
AEQK | PANEL SPACE HEIGHT | 61.250 INCHES NOMINAL |
SFTT | SURFACE TREATMENT | CHROMATE AND ZINC AND PAINT |
STYL | STYLE DESIGNATOR | ENCLOSED VERTICAL FRONT |