Part Number
Part Number:
NSN:
NIIN:
Item Name:
TRANSFORMER , PULSE
Definition:
A TRANSFORMER DESIGNED TO TRANSFER PULSES OF NONSINUSOIDAL WAVE FORMS BETWEEN CIRCUITS WITHOUT BASICALLY CHANGING THE WAVE FORMS.
CAGE Information
Code | Company |
---|---|
01961 | PULSE ENGINEERING INC |
Federal Supply Class
Title
COILS AND TRANSFORMERS
Inclusions:
INCLUDES COILS, EXCEPT IGNITION AND MAGNETO; COIL ASSEMBLIES; REACTORS; TRANSFORMERS.
Exclusions:
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
CRGS | DC RESISTANCE RATING IN OHMS | 9.800 SINGLE COMPONENT SINGLE PRIMARY |
ACYV | INDUCTANCE RATING | 14.00 MICROHENRIES NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
ADAU | BODY HEIGHT | 0.400 INCHES MAXIMUM |
CRCP | PEAK VOLTAGE RATING (NON-CORE) | 300.0 VOLTS SINGLE COMPONENT SINGLE PRIMARY |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
TTQY | TERMINAL TYPE AND QUANTITY | 5 PIN |
CRCP | PEAK VOLTAGE RATING (NON-CORE) | 300.0 VOLTS SINGLE COMPONENT SINGLE SECONDARY |
ADAQ | BODY LENGTH | 0.650 INCHES MAXIMUM |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ACYV | INDUCTANCE RATING | 14.00 MICROHENRIES NOMINAL SINGLE COMPONENT SINGLE SECONDARY |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 1 SECONDARY SINGLE COMPONENT |
ACZH | PRIMARY TO SECONDARY TURN RATIO | 1 TO 1 SINGLE COMPONENT |
ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD BROUGHT OUT TO TERMINAL SINGLE COMPONENT |
AXGY | MOUNTING METHOD | TERMINAL SINGLE GROUP |
ADAT | BODY WIDTH | 0.443 INCHES MAXIMUM |
CRGS | DC RESISTANCE RATING IN OHMS | 11.000 SINGLE COMPONENT SINGLE SECONDARY |
ACZL | PULSE RISE TIME IN MICROSECONDS (NON-CORE) | 0.080 SINGLE COMPONENT |