TRANSFORMER , POWER

Definition:

A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.

CAGE Information

Code Company
13483 PRECISION ELECTRONICS INC.

Federal Supply Class

Title

COILS AND TRANSFORMERS

Inclusions:

INCLUDES COILS, EXCEPT IGNITION AND MAGNETO; COIL ASSEMBLIES; REACTORS; TRANSFORMERS.

Exclusions:

Characteristics (Decoded)

MRC Requirements Statement Clear Text Reply
AKPV MOUNTING FACILITY QUANTITY 4 SINGLE GROUP
AKPV MOUNTING FACILITY QUANTITY 4 SINGLE GROUP
ABMK OVERALL WIDTH 4.250 INCHES NOMINAL
CQSJ INCLOSURE MATERIAL (NON-CORE) STEEL
CRBZ WINDING OPERATING CURRENT 250.0 MILLIAMPERES NOMINAL B AND BETTER DROP SIDING SINGLE COMPONENT SINGLE PRIMARY
AKNA INCLOSURE TYPE FULLY INCLOSED
BPLC WINDING FUNCTION AND QUANTITY 1 PRIMARY SINGLE COMPONENT AND 3 SECONDARY SINGLE COMPONENT
ABHP OVERALL LENGTH 5.250 INCHES NOMINAL
ACZC INPUT-OUTPUT PHASE RELATIONSHIP THREE PHASE TO THREE PHASE SINGLE COMPONENT
CWJS WINDING OPERATING VOLTAGE 16.20 AC POUNDS PER HOUR WET SINGLE COMPONENT 3RD SECONDARY
AARG RELIABILITY INDICATOR NOT ESTABLISHED
ABKR CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH 3.500 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
CWJS WINDING OPERATING VOLTAGE 200.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY
ABKQ CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH 4.500 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
AXGY MOUNTING METHOD UNTHREADED HOLE SINGLE GROUP
CBME CUBIC MEASURE (NON-CORE) 59.4 CUBIC INCHES
TTQY TERMINAL TYPE AND QUANTITY 1 CONNECTOR, RECEPTACLE
CWJS WINDING OPERATING VOLTAGE 20.30 AC POUNDS PER HOUR WET SINGLE COMPONENT 2ND SECONDARY
ACZB FREQUENCY RATING 400.0 HERTZ NOMINAL SINGLE COMPONENT
ACZD TRANSFORMER WINDING CONNECTION TYPE DELTA-DELTA
ABKW OVERALL HEIGHT 2.660 INCHES NOMINAL
CWJS WINDING OPERATING VOLTAGE 8.70 AC POUNDS PER HOUR WET SINGLE COMPONENT 1ST SECONDARY
ABTB MOUNTING HOLE DIAMETER 0.200 INCHES MINIMUM SINGLE GROUP AND 0.230 INCHES MAXIMUM SINGLE GROUP