Follow Us on Google+

Request A Price Quote:

Part Number

Part Number:
NSN:
NIIN:
Item Name:
TRANSFORMER , POWER

Definition:

A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.

CAGE Information

Code Company
13483 PRECISION ELECTRONICS INC.

Federal Supply Class

Title

COILS AND TRANSFORMERS

Inclusions:

INCLUDES COILS, EXCEPT IGNITION AND MAGNETO; COIL ASSEMBLIES; REACTORS; TRANSFORMERS.

Exclusions:

Characteristics (Decoded)

MRC Requirements Statement Clear Text Reply
AAJD THREAD CLASS (NON-CORE) 2B SINGLE GROUP
AKPV MOUNTING FACILITY QUANTITY 2 SINGLE GROUP
CWJS WINDING OPERATING VOLTAGE 8.00 AC POUNDS PER HOUR WET SINGLE COMPONENT ALL SECONDARY
THSD THREAD SERIES DESIGNATOR UNC SINGLE GROUP
AEJN DISTANCE BETWEEN MOUNTING FACILITY CENTERS 0.500 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
AAJF THREAD DIRECTION (NON-CORE) RIGHT-HAND SINGLE GROUP
CQLC WINDING TAP LOCATION (NON-CORE) CENTER TAP SINGLE COMPONENT ALL SECONDARY
AARG RELIABILITY INDICATOR NOT ESTABLISHED
AXGY MOUNTING METHOD THREADED HOLE SINGLE GROUP
TTQY TERMINAL TYPE AND QUANTITY 8 WIRE LEAD
AKNA INCLOSURE TYPE HERMETICALLY SEALED
BPLC WINDING FUNCTION AND QUANTITY 1 PRIMARY SINGLE COMPONENT AND 2 SECONDARY SINGLE COMPONENT
ADAU BODY HEIGHT 0.900 INCHES NOMINAL
CRBZ WINDING OPERATING CURRENT 3.0 MILLIAMPERES NOMINAL B AND BETTER DROP SIDING SINGLE COMPONENT ALL SECONDARY
CMLP THREAD QUANTITY PER INCH 40 SINGLE GROUP
CQJX NOMINAL THREAD SIZE 0.112 INCHES SINGLE GROUP
ACZB FREQUENCY RATING 400.0 HERTZ NOMINAL SINGLE COMPONENT
ACZC INPUT-OUTPUT PHASE RELATIONSHIP SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
ADAT BODY WIDTH 0.900 INCHES NOMINAL
ADAQ BODY LENGTH 0.900 INCHES NOMINAL
CWJS WINDING OPERATING VOLTAGE 121.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY

Similar Parts

PEI7804 , PEI7804 , 5950-00-964-9413 , 5950009649413 , 009649413