Follow Us on Google+

Request A Price Quote:

Part Number

Part Number:
NSN:
NIIN:
Item Name:
CIRCUIT BREAKER

Definition:

A DEVICE WITH MEANS OTHER THAN FUSES FOR AUTOMATICALLY OPENING THE CIRCUIT IN WHICH IT IS INSTALLED WHEN THE CURRENT VARIES FROM THE PREDETERMINED VALUE FOR WHICH THE DEVICE IS SET. MAY INCLUDE PROVISIONS FOR MANUAL OPERATION. AT LEAST ONE SET OF CONTACTS MUST BE IN SERIES WITH THE ACTUATING ELEMENT(S). A COMBINATION OF SEMICONDUCTOR AND PASSIVE DEVICES MAY BE USED IN LIEU OF CONTACTS. FOR AUTOMATICALLY OPERATED ITEMS IN WHICH THE ACTUATING (TRIPPING) ELEMENT AND CONTACTS ARE NOT IN SERIES, SEE RELAY (AS MODIFIED). FOR ITEMS WHICH ARE OPERATED BOTH MANUALLY AND AUTOMATICALLY BUT THE ACTUATING ELEMENTS AND CONTACT ARE NOT IN SERIES, SEE RELAY-SWITCH. EXCLUDES CIRCUIT BREAKER BOX AND MAGNETO "BREAKER" ASSEMBLIES. SEE ALSO SWITCH (AS MODIFIED); AND CONTROLLER.

CAGE Information

Code Company
35181 CAE INC

Characteristics (Decoded)

MRC Requirements Statement Clear Text Reply
AKPX POLE QUANTITY 4
AEBY DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH 63.5 MILLIMETERS NOMINAL
AEBP CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH 5.9 MILLIMETERS NOMINAL
CPRQ RESET METHOD MANUAL
AJWX MOUNTING SURFACE TO TERMINAL END DISTANCE 49.0 MILLIMETERS NOMINAL
CPRJ TRIP RELEASE METHOD MAGNETIC ALL LOCATIONS
AEBQ CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH 19.0 MILLIMETERS NOMINAL
ABXD BUSHING LENGTH 3.5 MILLIMETERS NOMINAL
AEHA DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH 19.0 MILLIMETERS NOMINAL
AAQL BODY STYLE MULTIPOLE-MULTIPLE ACTUATOR TYPE
ADAQ BODY LENGTH 92.0 MILLIMETERS NOMINAL
CXCY PART NAME ASSIGNED BY CONTROLLING AGENCY MOUNT MAGNETIC CIRCUIT BREAKER

Similar Parts