Follow Us on Google+

Request A Price Quote:

Part Number

Part Number:
NSN:
NIIN:
Item Name:
RELAY , ELECTROMAGNETIC

Definition:

A RELAY WHICH IS ACTUATED BY THE EFFECT OF A MAGNETIC FIELD DEVELOPED BY THE CURRENT IN ITS ENERGIZING COIL(S). INCLUDES SOLENOID AND ARMATURE TYPES. EXCLUDES CONTACTOR, MAGNETIC; RELAY, METER MOVEMENT; RELAY, MOTOR DRIVEN; RELAY, REED; RELAY, RESONANT REED; RELAY, ROTARY; AND SWITCH, STEPPING.

CAGE Information

Code Company
04939 LOCKHEED MARTIN CORPORATION DBA LOCK

Federal Supply Class

Title

RELAYS AND SOLENOIDS

Inclusions:

INCLUDES ELECTROMAGNETIC ACTUATORS.

Exclusions:

EXCLUDES CONTRACTORS.

Characteristics (Decoded)

MRC Requirements Statement Clear Text Reply
CTDL MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE 1.0 AMPERES AC RESISTIVE LOAD AND 2.0 AMPERES DC RESISTIVE LOAD
CSXF OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP 24.0 VOLTS TEARDROP, TWO HOLES TYPE 4F ALL WINDINGS
AKDX WINDING QUANTITY 2
ABHP OVERALL LENGTH 1.180 INCHES NOMINAL
ABKW OVERALL HEIGHT 0.390 INCHES NOMINAL
APCN COIL QUANTITY 1
AEBV UNTHREADED MOUNTING HOLE DIAMETER 0.098 INCHES NOMINAL SINGLE MOUNTING FACILITY
ABKQ CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH 1.000 INCHES NOMINAL SINGLE MOUNTING FACILITY
AXHR MOUNTING FACILITY TYPE AND QUANTITY 2 UNTHREADED HOLE SINGLE MOUNTING FACILITY
CWAB MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS 115.0 AC AND 30.0 DC
ADZC ENVIRONMENTAL PROTECTION HERMETIC
TTQY TERMINAL TYPE AND QUANTITY 8 PIN ALL FUNCTIONS
APNP DUTY TYPE CONTINUOUS
APNQ ARC QUENCHING METHOD INERT GAS
CRNG NONPILE-UP MAIN CONTACT ARRANGEMENT 2 POLE, DOUBLE THROW, ONE POSITION MOMENTARY
APNA WINDING DC RESISTANCE RATING 630.0 OHMS NOMINAL ALL WINDINGS
CQYJ MOUNTING FACILITY PATTERN IN-LINE SINGLE MOUNTING FACILITY
CBBL FEATURES PROVIDED POLARIZED AND LATCHING CONTACTS
ABMK OVERALL WIDTH 1.100 INCHES NOMINAL

Similar Parts

PS723000012F001 , PS723000012F001 , 5945-00-959-6309 , 5945009596309 , 009596309