Definition:
A CHAMBER DESIGNED EXCLUSIVELY TO PERFORM CONTROLLED TESTS UNDER SIMULATED ENVIRONMENTAL CONDITIONS TO DETERMINE PHYSICAL CHANGES OR DAMAGE TO ITEMS UNDER TEST DUE TO HUMIDITY, IMMERSION, MOISTURE, ALTITUDE THERMAL SHOCK, SAND, DUST, ETC..
CAGE Information
Code | Company |
---|---|
57187 | GULTON-STATHAM TRANSDUCERS INC |
Federal Supply Class
Title
ENVIRONMENTAL CHAMBERS AND RELAT
Inclusions:
INCLUDES CHAMBERS; WIND TUNNELS; ENCLOSURES SPECIFICALLY DESIGNED TO SIMULATE AN ENVIRONMENTAL CONDITION; WEATHEROMETERS; FADEOMETERS; SPECIALLY DESIGNED EQUIPMENT AND COMPONENTS EXCLUSIVELY RELATED TO ENVIRONMENTAL CHAMBERS.
Exclusions:
EXCLUDES GENERAL PURPOSE PREFABRICATED BUILDINGS, CHAMBERS, PANELS, AND COMPONENTS (FSC 5410); CONTROLLED ENVIRONMENTAL CONDITIONING KITS AND SETS (FSC 4240); BATHS (FSC 4510); OVENS (FSC 7310); KILNS (FSC 3630); RADIOSONDE BASELINE CHECK SETS (FSC 6660); DIVERS RECOMPRESSION CHAMBERS (FSC 4220); ALTITUDE TRAINING DECOMPRESSION CHAMBERS (FSC 6930); AND CHAMBERS USED AS TRAINING DEVICES (FSC 6930); CHECKOUT AND TEST EQUIPMENT (FSC 6625); CHEMICAL ANALYSIS INSTRUMENTS (FSC 6630); ELECTRICAL AND ELECTRONIC PROPERTIES MEASURING AND TESTING INSTRUMENTS (FSC 6625); AND METEOROLOGICAL INSTRUMENTS (FSC 6660).
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
ABKW | OVERALL HEIGHT | 42.750 INCHES NOMINAL |
ASQJ | OPERATING TEMP RANGE IN DEG CELSIUS | +65.6/+204.7 |
ABFY | OVERALL DEPTH | 32.000 INCHES NOMINAL |
CWZY | ENVIRONMENTAL CHAMBER TYPE | TEMPERATURE |
AFMQ | INSIDE HEIGHT | 28.750 INCHES NOMINAL |
ABMK | OVERALL WIDTH | 46.000 INCHES NOMINAL |
AKYD | ACCESSORY COMPONENTS AND QUANTITY | ADJUSTABLE OVERTEMPERAYURE FAILSAFE; INDICATING PYROMETER (OPT); TEMPERATURE SET POINT DIAL; TEMP. INDICATINGNULL BALANCEMETER PORM 2.0 DEG. C.; BLOWER MOTOR |
FEAT | SPECIAL FEATURES | CONTROL ACCURACY PORM 0.9 DEG. F.; HORIZONAL AIR FLOW |
ADJT | INSIDE WIDTH | 32.000 INCHES NOMINAL |
AMSE | VOLTAGE RATING | 220.0 VOLTS NOMINAL |
ACZB | FREQUENCY RATING | 50.0 HERTZ MINIMUM AND 60.0 HERTZ MAXIMUM |
ACDC | CURRENT TYPE | AC |
ANPT | POWER RATING | 4.0 KILOVOLT-AMPERE NOMINAL |
AFEF | INSIDE DEPTH | 24.000 INCHES NOMINAL |
FAAZ | PHASE | SINGLE |