Part Number
Part Number:
NSN:
NIIN:
Item Name:
RESISTOR , THERMAL
Definition:
A THERMALLY SENSITIVE RESISTOR WHOSE PRIMARY FUNCTION IS TO EXHIBIT A CHANGE IN ELECTRICAL RESISTANCE WITH A CHANGE IN BODY TEMPERATURE. ITEM MAY BE MOUNTED IN A PROBE OR HOUSING. FOR BALLAST TUBE TYPE RESISTORS, SEE RESISTOR (1), CURRENT REGULATING. EXCLUDES TRANSMITTER (1), TEMPERATURE, ELECTRICAL RESISTANCE AND TEMPERATURE ELEMENT, RESISTANCE METEOROLOGICAL.
CAGE Information
Code | Company |
---|---|
51406 | MURATA ERIE NORTH AMERICA INC HEADQU |
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 1.5 KILOHMS 9TH RESISTANCE-TEMPERATURE POINT |
ADAU | BODY HEIGHT | 1.730 INCHES NOMINAL |
AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 20.0 OHMS 7TH RESISTANCE-TEMPERATURE POINT |
AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 140.0 DEG CELSIUS 9TH RESISTANCE-TEMPERATURE POINT |
TTQY | TERMINAL TYPE AND QUANTITY | 2 TAB, SOLDER LUG |
ABJT | TERMINAL LENGTH | 0.231 INCHES MINIMUM AND 0.241 INCHES MAXIMUM |
AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 130.0 DEG CELSIUS 8TH RESISTANCE-TEMPERATURE POINT |
AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 40.0 DEG CELSIUS 3RD RESISTANCE-TEMPERATURE POINT |
AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 9.0 OHMS 4TH RESISTANCE-TEMPERATURE POINT |
AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | -20.0 DEG CELSIUS 1ST RESISTANCE-TEMPERATURE POINT |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 1.260 INCHES NOMINAL |
ABHP | OVERALL LENGTH | 3.222 INCHES NOMINAL |
AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 60.0 OHMS 8TH RESISTANCE-TEMPERATURE POINT |
STYL | STYLE DESIGNATOR | BEAD IN CAN |
ADAQ | BODY LENGTH | 2.750 INCHES NOMINAL |
AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 11.0 OHMS 2ND RESISTANCE-TEMPERATURE POINT |
AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.157 INCHES NOMINAL |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
AEBT | TERMINAL DIAMETER | 0.630 INCHES NOMINAL |
AEHY | AMBIENT TEMP AT FULL RATED POWER | 25.0 DEG CELSIUS |
AKNA | INCLOSURE TYPE | ENCAPSULATED |
AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 120.0 DEG CELSIUS 7TH RESISTANCE-TEMPERATURE POINT |
AEJN | DISTANCE BETWEEN MOUNTING FACILITY CENTERS | 2.280 INCHES NOMINAL |
AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 100.0 DEG CELSIUS 6TH RESISTANCE-TEMPERATURE POINT |
AGAV | END ITEM IDENTIFICATION | RANSMITTERRF7 |
AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 11.0 OHMS 6TH RESISTANCE-TEMPERATURE POINT |
AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 150.0 DEG CELSIUS 10TH RESISTANCE-TEMPERATURE POINT |
AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 70.0 DEG CELSIUS 5TH RESISTANCE-TEMPERATURE POINT |
AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 10.0 KILOHMS 10TH RESISTANCE-TEMPERATURE POINT |
AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 14.0 OHMS 1ST RESISTANCE-TEMPERATURE POINT |
ADAT | BODY WIDTH | 0.865 INCHES NOMINAL |
CRQJ | ZERO POWER RESISTANCE TOLERANCE IN PERCENT AT REFERENCE TEMP | -30.0/+30.0 |
AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 60.0 DEG CELSIUS 4TH RESISTANCE-TEMPERATURE POINT |
AEJF | RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -30.0/+30.0 ALL RESISTANCE-TEMPERATURE POINTS |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 2.260 INCHES MINIMUM AND 2.300 INCHES MAXIMUM |
AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 9.5 OHMS 3RD RESISTANCE-TEMPERATURE POINT |
AEHZ | MAXIMUM OPERATING TEMP | 150.0 DEG CELSIUS |
CQWD | ZERO POWER RESISTANCE | 10.000 OHMS |
AEHX | MAXIMUM POWER DISSIPATION RATING | 10.00 WATTS |
AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 10.0 DEG CELSIUS 2ND RESISTANCE-TEMPERATURE POINT |
AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 8.5 OHMS 5TH RESISTANCE-TEMPERATURE POINT |