Part Number
Definition:
A RIGID OR FLEXIBLE TUBING HAVING UNIFORM INSIDE AND OUTSIDE DIAMETERS IN THE OVERALL LENGTH. IT IS SPECIFICALLY DESIGNED TO PREVENT ANY UNDESIRABLE FLOW OF CURRENT BETWEEN CONDUCTORS AND OTHER OBJECTS. INCLUDES SHRINKABLE TYPE TUBING, ITEMS IN BULK AND IN SPECIFIC FABRICATED LENGTHS (CUT TO SIZE). EXCLUDES ITEMS NOT HAVING RATED ELECTRICAL CHARACTERISTICS. ALSO EXCLUDES BUSHING, SLEEVE; CABLE NIPPLE, ELECTRICAL; CONDUIT (AS MODIFIED); INSULATION SLEEVING, ELECTRICAL, SPECIAL PURPOSE; INSULATION SLEEVING, THERMAL; SLEEVE, MARKER, CABLE; SLEEVING, TEXTILE, ELECTRICAL; TUBING, GLASS; AND TUBING, NONMETALLIC.
CAGE Information
Code | Company |
---|---|
92194 | ALPHA WIRE CORP |
Federal Supply Class
Title
ELECTRICAL INSULATORS AND INSULA
Inclusions:
INCLUDES TUBE, KNOB, CLEAT, STRAIN, AND STANDOFF INSULATORS; FEED THRU INSULATORS; BEAD INSULATORS; VARNISH CAMBRIC TAPE; FRICTION TAPE.
Exclusions:
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AARX | INSIDE DIAMETER | 0.144 INCHES MINIMUM AND 0.158 INCHES MAXIMUM |
HUES | COLOR | BLACK |
ZZZW | DEPARTURE FROM CITED DOCUMENT | AS MOD BY COLOR |
FLEX | FLEXIBILITY | FLEXIBLE |
ZZZT | NONDEFINITIVE SPEC/STD DATA | 7 AWG SIZE AND C GRADE AND U FORM AND 1 CLASS AND 1 CATEGORY AND UA SUBFORM AND F TYPE |
UKBG | DIELECTRIC MATERIAL VOLTAGE RATING PER UNIT THICKNESS | 700.0 VOLTS PER MIL /0.001 INCH/ |
ABJH | TEMP RATING | -10.0 DEG CELSIUS AND 105.0 DEG CELSIUS |
AAGT | WALL THICKNESS | 0.017 INCHES MINIMUM AND 0.023 INCHES MAXIMUM |
MATL | MATERIAL | PLASTIC, POLYVINYL CHLORIDE |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
FEAT | SPECIAL FEATURES | MATERIAL SPEC: MIL-I-631, TYPE F, FORM U, SUBFORM UA, GRADE C, CLASS 1, CATEGORY 1 |
STYL | STYLE DESIGNATOR | NONSHRINKABLE |
CQBC | MINIMUM TENSILE STRENGTH | 1800 POUNDS PER SQUARE INCH |
ADZC | ENVIRONMENTAL PROTECTION | OIL RESISTANT AND MILDEW RESISTANT AND FLAME RESISTANT AND HEAT RESISTANT |