Part Number
Part Number:
NSN:
NIIN:
Item Name:
MOTOR , CONTROL
Definition:
A MOTOR WHICH IS DESIGNED TO BE OPERATED FROM TWO INDEPENDENT VOLTAGE SOURCES, IN SUCH A WAY THAT VARIATIONS IN ONE VOLTAGE SOURCE WILL DETERMINE THE DIRECTION AND SPEED OF THE MOTOR. IN THE ALTERNATING CURRENT TYPE THE VOLTAGES ARE USUALLY APPLIED TO A SPLIT-PHASE STATOR, WHEREAS IN THE DIRECT CURRENT TYPE, ONE VOLTAGE IS APPLIED TO THE STATOR AND THE OTHER TO THE ARMATURE. LOW INERTIA AND RAPID REVERSIBILITY ARE INHERENT CHARACTERISTICS OF THIS TYPE OF MOTOR. SEE ALSO SERVOMOTOR, AUTOMATIC PILOT.
CAGE Information
Code | Company |
---|---|
S3092 | RHEINMETALL AIR DEFENCE AG |
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
ABWV | SHAFT DIAMETER | 0.2487 INCHES MINIMUM SINGLE END AND 0.2497 INCHES MAXIMUM SINGLE END |
ACDC | CURRENT TYPE | AC INPUT |
BKPB | CURRENT RATING METHOD | LOCKED ROTOR |
CWDY | TEMP RATING | -54.0 OPERATING DEG CELSIUS AND 165.0 OPERATING DEG CELSIUS |
CWGQ | CONNECTION TYPE AND VOLTAGE RATING IN VOLTS | 36.0 LINE TO NEUTRAL SECOND MULTIPLE INPUT OR 115.0 LINE TO NEUTRAL FIRST MULTIPLE INPUT OR 18.0 LINE TO NEUTRAL THIRD MULTIPLE INPUT |
CWHZ | SHAFT END CHARACTERISTIC | A1 SINGLE STYLE SINGLE END |
CWGL | CURRENT RATING IN AMPS | 0.420 FIRST MULTIPLE INPUT OR 1.340 SECOND MULTIPLE INPUT OR 2.680 THIRD MULTIPLE INPUT |
ANPZ | INCLOSURE FEATURE | GENERAL PURPOSE |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 1 CLAMP COLLAR AND 4 THREADED HOLE |
FREQ | FREQUENCY IN HERTZ | 400.0 INPUT |
AAJV | OVERALL WIDTH | 2.2465 INCHES |
TTQY | TERMINAL TYPE AND QUANTITY | 6 WIRE LEAD |
BKPH | TORQUE RATING AND TYPE | 6.5 INCH-OUNCES STALLED |
CBBL | FEATURES PROVIDED | VERTICAL MOUNTING POSITION AND HORIZONTAL MOUNTING POSITION |
AAJU | OVERALL LENGTH | 2.914 INCHES |
AXGY | MOUNTING METHOD | CLAMP RING |
CWCS | LENGTH OF SHAFT FROM HOUSING | 0.503 INCHES SINGLE END |
FAAZ | PHASE | TWO INPUT |
CWFX | ROTOR SPEED RATING IN RPM | 1000.0 LOW NO LOAD |
BFML | CONTROL FIELD WINDING TYPE | SINGLE WINDING OR TWO WINDINGS, SERIES CONNECTED |
BFMF | COOLING METHOD | NONVENTILATED |