Part Number
Part Number:
NSN:
NIIN:
Item Name:
CIRCUIT BREAKER
Definition:
A DEVICE WITH MEANS OTHER THAN FUSES FOR AUTOMATICALLY OPENING THE CIRCUIT IN WHICH IT IS INSTALLED WHEN THE CURRENT VARIES FROM THE PREDETERMINED VALUE FOR WHICH THE DEVICE IS SET. MAY INCLUDE PROVISIONS FOR MANUAL OPERATION. AT LEAST ONE SET OF CONTACTS MUST BE IN SERIES WITH THE ACTUATING ELEMENT(S). A COMBINATION OF SEMICONDUCTOR AND PASSIVE DEVICES MAY BE USED IN LIEU OF CONTACTS. FOR AUTOMATICALLY OPERATED ITEMS IN WHICH THE ACTUATING (TRIPPING) ELEMENT AND CONTACTS ARE NOT IN SERIES, SEE RELAY (AS MODIFIED). FOR ITEMS WHICH ARE OPERATED BOTH MANUALLY AND AUTOMATICALLY BUT THE ACTUATING ELEMENTS AND CONTACT ARE NOT IN SERIES, SEE RELAY-SWITCH. EXCLUDES CIRCUIT BREAKER BOX AND MAGNETO "BREAKER" ASSEMBLIES. SEE ALSO SWITCH (AS MODIFIED); AND CONTROLLER.
CAGE Information
Code |
Company |
S3092 |
RHEINMETALL AIR DEFENCE AG |
Characteristics (Decoded)
MRC |
Requirements Statement |
Clear Text Reply |
BBRJ |
SPECIAL HANDLING FEATURE |
MAGNETIC |
CQJX |
NOMINAL THREAD SIZE |
0.469 INCHES |
BBRG |
STORAGE TYPE |
GENERAL PURPOSE WAREHOUSE |
CPRH |
CIRCUIT PROTECTION TYPE |
OVERCURRENT SINGLE LOCATION |
AXHR |
MOUNTING FACILITY TYPE AND QUANTITY |
1 THREADED BUSHING |
ADAQ |
BODY LENGTH |
1.781 INCHES NOMINAL |
CPRZ |
AUXILIARY SWITCH FUNCTION AND QUANTITY |
1 ALARM |
PKWT |
UNPACKAGED UNIT WEIGHT |
2.000 OUNCES |
AAQL |
BODY STYLE |
SINGLE POLE TYPE |
CSWP |
SWITCH VOLTAGE RATING AND TYPE IN VOLTS |
130.0 AC AND 28.0 DC |
AFJN |
FRAGILITY FACTOR |
MODERATELY RUGGED |
CQWN |
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT |
0.110 MINIMUM AT 200 PCT SINGLE LOCATION AND 2.000 MAXIMUM AT 200 PCT SINGLE LOCATION |
CPSM |
INTERNAL TRIP RELEASE CONFIGURATION |
SERIES TRIP SINGLE LOCATION |
TTQY |
TERMINAL TYPE AND QUANTITY |
2 TAB W/SCREW |
CPRR |
MAIN CONTACT TRIPPING MECHANISM TYPE |
TRIP FREE |
CPRJ |
TRIP RELEASE METHOD |
MAGNETIC SINGLE LOCATION |
AEBP |
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH |
1.341 INCHES NOMINAL |
THSD |
THREAD SERIES DESIGNATOR |
UNS |
CPRF |
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS |
32.0 DC SINGLE LOCATION |
AEGJ |
SWITCH CONTACT ARRANGEMENT |
SINGLE POLE, DOUBLE THROW |
CQSM |
SWITCH LOCATION AND POSITION DESIGNATION |
INTERNAL AT POLE ONE |
ADTV |
CASE MATERIAL |
PLASTIC |
AKPX |
POLE QUANTITY |
1 |
CPRQ |
RESET METHOD |
MANUAL |
CPRG |
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS |
2000.0 DC SINGLE LOCATION |
ADAT |
BODY WIDTH |
0.656 INCHES NOMINAL |
CSSX |
SWITCH CURRENT RATING AND TYPE IN AMPS |
7.0 AC AND 7.0 DC |
CPLM |
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE |
15.0 AMPERES DC SINGLE LOCATION |
CPRT |
MANUAL ACTUATOR TYPE AND QUANTITY |
1 PUSH-PULL |
CPRW |
ACTUATOR FUNCTION |
TRIP-RESET |
CPRN |
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT |
135.0 SINGLE LOCATION |
APNQ |
ARC QUENCHING METHOD |
MAGNETIC BLOWOUT |
CQXF |
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED |
FUNGUS RESISTANT AND DUSTTIGHT AND SAND RESISTANT AND CORROSION RESISTANT |
CRTK |
SWITCH TERMINAL TYPE |
TURRET |
CPRX |
ACTUATOR POSITION DESIGNATION |
AT POLE ONE |
CMLP |
THREAD QUANTITY PER INCH |
32 |
CPRL |
TRIP RELEASE CHARACTERISTIC |
TIME DELAY SINGLE LOCATION |
AJWX |
MOUNTING SURFACE TO TERMINAL END DISTANCE |
1.669 INCHES NOMINAL |
ABXD |
BUSHING LENGTH |
0.250 INCHES NOMINAL |
Similar Parts